beautypg.com

Dell OptiPlex E1 User Manual

Page 84

background image

The conflicting

resource was:

resource.

one at a time, beginning with the new card and resolving resource
conflicts as they arise. See "

Removing a Card

" and "

Adding a Listed

Card

" or "

Adding an Unlisted Card

" for instructions.

If you cannot resolve the resource conflict by any of the preceding

methods, remove the new card. If you were modifying an existing

card, reset the modified card to its previous resource value.

The

configuration

(.cfg) file used

by

the ICU for this

card is now

invalid

or does not

exist.

Do you wish to

load

the file?

No

configuration

(.cfg) file exists

for the card

being

modified. Do

you

want to load

one?

This message appears

when you try to add a

listed card and the

configuration file for this card

has been corrupted or

deleted from the

database.

This message appears when

you modify a card and its

configuration file does not

exist or has been deleted.

You can get a copy of the configuration file from the original ISA

Configuration Utility Diskette that you used to create the backup ICU diskette.

Use the following procedure:

1. Insert the original ISA Configuration Utility Diskette into drive A.
2. Change to the db subdirectory on the diskette drive.

For example, type cd a:\db.

3. Use a text editor to search the icu.ndx file for the card ID of the

card you want to add or modify.

The name of the configuration file is part of this card ID. For example,
if the card ID is ICU0200, the configuration file is !icu0200.cfg

4.

Copy the configuration file from the original ICU diskette to the

backup diskette.

This is an EISA

system. Use an

ECU,

not the ICU, to

configure your

system.

This message appears if

you attempt to run the ICU on

an EISA system.

To use the ICU, you must load the utility onto a non-EISA system.

You have

added a

card using

settings

different from

factory default.

Reconfigure the

card to the

settings in the

next

display (see the

card's manual)

before installing

it.

This message can appear

in two situations:

You added an ISA
expansion card,
selected OK, and the
ICU had to use
resource values
different from the
card's defaults to
avoid conflicts.

You added an ISA

expansion card,

selected Advanced,

and chose resource

values different from

Make note of the new card configuration shown in the Card Resource Usage

dialog box displayed after this message. Change jumper settings on the ISA

expansion card to match the new card configuration.