Dell PowerVault DR6000 User Manual
Page 120

Error Code
Message Information
SEL0008
Message
Log is full.
Details
When the event log is full, additional events are not written
to the log. Older events may be overwritten and lost. This
message may also appear if the user disabled event logging.
Action
Backup and clear log.
SEL0012
Message
Could not create or initialize the system event log.
Details
If the system event log fails to initialize, platform status and
failure events are not captured. Some management software
do not report platform exceptions.
Action
Reboot the management controller or iDRAC. Cycle system
input power. If problem persists call support.
SEL1204
Message
An unknown system hardware failure detected.
Details
If the system event log failed to initialize, platform status and
failure events are not captured. Some management software
do not report platform exceptions.
Action
Re-configure system to the minimum supported
configuration. If issues persists, contact support.
TMP0118
Message
The system inlet temperature is less than the lower warning
threshold.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0119
Message
The system inlet temperature is less than the lower critical
threshold.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0120
Message
The system inlet temperature is greater than the upper
warning threshold.
Details
Ambient air temperature is too warm or one or more fans
may have failed.
Action
Check the system operating environment and review event
log for fan failures.
120