Dell PowerVault DR6000 User Manual
Page 115

Error Code
Message Information
PDR1016
Message
Drive <number> is removed from disk drive bay <bay>.
Details
The controller detected that the drive was removed.
Action
Verify drive installation. Re-seat the failed drive. If the issue
persists, see
PST0128
Message
No memory is detected.
Details
System BIOS was unable to detect memory in the system.
Action
Re-seat the memory modules. If the issue persists, see
.
PST0129
Message
Memory is detected, but is not configurable.
Details
System BIOS detected memory, but was unable to configure
the memory for system operation.
Action
Compare system memory installation to supported system
memory configurations.
PSU0001
Message
Power supply <number> failed.
Action
Remove and reinstall the power supply. If the issue persists,
see
PSU0002
Message
A predictive failure detected on power supply <number>.
Details
System performance and power redundancy may be
degraded or lost.
Action
Remove and reinstall the power supply at the next service
window. If the issue persists, see
PSU0003
Message
The power input for power supply <number> is lost.
Details
The power supply is installed correctly but an input source is
not connected or is not functional.
Action
Verify the input source is attached to the power supply.
Verify the input power is within the operating requirements
for the power supply.
PSU0006
Message
Power supply <number> type mismatch.
Details
Power supplies should be of the same input type and power
rating.