Error Code
Message Information
5.
If the issue persists, see
CPU0704
Message
CPU <number> machine check error detected.
Details
System event log and operating system logs may indicate
that the exception is external to the processor.
Action
1.
Check system and operating system logs for exceptions.
If no exceptions are found, continue.
2.
Turn off the system and remove input power for one
minute.
3.
Ensure the processor is seated correctly.
4.
Reapply input power and turn on the system.
5.
If the issue persists, see
FAN0000
Message
Fan <number> RPM is less than the lower warning threshold.
Details
Fan operating speed is out of range.
Action
Remove and reinstall the fan. If the issue persists, see
.
FAN0001
Message
Fan <number> RPM is less than the lower critical threshold.
Details
Fan operating speed is out of range.
Action
Remove and reinstall the fan. If the issue persists, see
.
FAN1201
Message
Fan redundancy is lost.
Details
Fan has failed.
Action
Remove and reinstall failed fans or install additional fans.
HWC1001
Message
The <name> is absent.
Details
The absent device may be necessary for proper operation.
System functionality may be degraded.
Action
Reinstall or reconnect the hardware.
HWC2003
Message
The storage <name> cable is not connected, or is improperly
connected.
Details
The cable may be necessary for proper operation. System
functionality may be degraded.