Dell PowerVault DR6000 User Manual
Page 109

Error Code
Message Information
Details
System Event Log and Operating System Logs may indicate
that the exception is external to the processor.
Action
Review System Event Log and Operating System Logs. If the
issue persists, see
.
CPU0001
Message
CPU <number> has a thermal trip (over-temperature) event.
Details
The processor temperature increased beyond the
operational range.
Action
Review the logs for fan failures. If no fan failures are
detected, check inlet temperature (if available) and reinstall
processor heat sink. If the problem persists, see
.
CPU0005
Message
CPU <number> configuration is unsupported.
Details
System is unable to boot or may run in a degraded state.
Action
Review the technical specifications for supported processor
types.
CPU0010
Message
CPU <number> is throttled.
Details
The CPU is throttled due to thermal or power conditions.
Action
Review system logs for power or thermal exceptions.
CPU0023
Message
CPU <number> is absent.
Action
Verify processor installation. If present, re-seat the
processor.
CPU0204
Message
CPU <number> <name> voltage is outside of range.
Details
Voltages outside the allowable range may damage electrical
components or may cause the system to shutdown.
Action
1.
Turn off the system and remove input power for one
minute.
2.
Ensure the processor is seated correctly.
3.
Reapply input power and turn on the system.
4.
If the issue persists, see
CPU0700
Message
CPU <number> initialization error detected.
Details
System BIOS was unable to initialize the processor.
109