Dell PowerVault DR6000 User Manual
Page 116

Error Code
Message Information
Action
Install matched power supplies and review proper
configuration in this manual.
PSU0016
Message
Power supply <number> is absent.
Details
The power supply has been removed or has failed.
Action
1.
Remove and reinstall the power supply.
2.
Check cables and subsystem components in the system
for damage.
3.
PSU0031
Message
Cannot communicate with power supply <number>.
Details
The power supply may operate, however power supply
monitoring is degraded. System performance may be
degraded.
Action
Remove and reinstall the power supply. If the issue persists,
see
PSU0032
Message
The temperature for power supply <number> is in a warning
range.
Details
System performance may be degraded.
Action
Check the system operating environment, including airflow
and inlet temperature. Check system logs for temperature
and thermal component failures.
PSU0033
Message
The temperature for power supply <number> is outside of
the allowable range.
Details
System performance may be degraded.
Action
Check the system operating environment, including airflow
and inlet temperature. Check system logs for temperature
and thermal component failures.
PSU0034
Message
An under voltage fault detected on power supply <number>.
Details
This failure may be the result of an electrical issue with
cables or subsystem components in the system.
Action
1.
Remove and reinstall the power supply.
2.
Check cables and subsystem components in the system
for damage.
116