Dell PowerVault DR6000 User Manual
Page 112

Error Code
Message Information
Action
Check if the cable is present, then reinstall or reconnect.
HWC2005
Message
The system board <name> cable is not connected, or is
improperly connected.
Details
The cable may be necessary for proper operation. System
functionality may be degraded.
Action
Check if the cable is present, then reinstall or reconnect.
MEM0000
Message
Persistent correctable memory errors detected on a memory
device at location(s) <location>.
Details
This is an early indicator of a possible future uncorrectable
error.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM0001
Message
Multi-bit memory errors detected on a memory device at
location(s) <location>.
Details
The memory module has encountered an uncorrectable
error. System performance may be degraded. The operating
system and/or applications may fail as a result.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM0007
Message
Unsupported memory configuration; check memory device
at location <location>.
Details
The memory may not be seated correctly, misconfigured, or
has failed. Memory size is reduced.
Action
Check the memory configuration. Re-seat the memory
modules. If the issue persists, see
MEM0701
Message
Correctable memory error rate exceeded for <location>.
Details
The memory may not be operational. This an early indicator
of a possible future uncorrectable error.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM0702
Message
Correctable memory error rate exceeded for <location>.
112