Single surface mount warning system, Flash pattern and id# setup – SoundOff Signal Predator 2 Surface Mount Light ECE User Manual
Page 2

EP2SSMDBx-EC 10.10
SINGLE SURFACE MOUNT
WARNING SYSTEM
Flash Pattern and ID# Setup
Predator Sync Configuration Instructions
IMPORTANT! A MAXIMUM OF 4 SINGLE LIGHTS
CAN BE SYNCED TOGETHER
1. Set ID#
a. Identify which pattern and sequence you want and look up ID# settings below.
b.
Connections
i. RED:
+12Vdc
ii. WHT: +12Vdc (Note: you will need to disconnect after power is applied)
iii.
BLK:
Ground
c. Apply power to unit
d. Without disconnecting power from unit, disconnect WHT wire
e. Momentarily connect WHT to Ground to change ID #
i. Identify ID# by number of sequential flashes
ii. Possible ID#s: 1 – 4
f. Disconnect power from unit to get out of ID mode.
2. Set Pattern
a. Reapply power to units.
b. Once all Light Head ID#s are configured, make sure all lights are flashing the same
pattern
c. Connect corresponding colored wires of all units together: RED to RED, etc.
d.
Change
Pattern
i. Momentarily connect WHT wires to Ground
ii. Observe pattern change on all lights connected
e. Insulate all wires by taping with electrical tape
3. Connect Master Switch for Application
a.
IMPORTANT! Ensure WHT Pattern/Sync Wires are tied together
1 LIGHT
Single Light Operation: Follow the ID Selection steps and set the PREDATOR II to ID#1 if it
is not already.
2 LIGHTS
ALTERNATING: To obtain Alternating patterns, follow the ID SELECTION steps and set
one PREDATOR II to ID#1 and the other to ID#3. Then proceed to the PATTERN
SELECTION steps.
SIMULTANEOUS: To obtain Simultaneous patterns, follow the ID SELECTION steps and
set both PREDATOR II lights to ID#1. Then proceed to PATTERN SELECTION steps.
All patterns above are ECE R65 certified if
they are set up as shown in “1 LIGHT” and
“2 LIGHTS”.
Flash Patterns
Patterns
FPM
(Flashes per Minute)
1. Single
125
2. Double
125
3. Triple
123