2.2.2 Key Indicators
The key indicators at the bottom of the display indicate the states of the keys directly
below them. In figure 2.2, the keys are set to PROGRAM, OIM, MANUAL, and
FORWARD. Key indicators are described in table 2.4.
Interlock OK
On
The terminal strip function loss input is
closed. See the hardware I/M for more
information. Also see the description of
Function Loss Response (P.026) in the
software I/M for a description of the types of
responses available on function loss.
Off
The terminal strip function loss input is open.
See the hardware I/M for more information.
Drive Ready
On
The drive is ready to run or jog. See chapter
7 for more information.
Off
The drive is not ready. See chapter 7 for
more information.
Running
On
Output power is being applied to the motor
(the motor is running or jogging).
Off
Output power is not being applied to the
motor.
Current Limit
Torque Limit
On
The drive is in current or torque limit.
Off
The drive is not in current or torque limit.
Table 2.3 – Drive Status Indicators (Continued)
Indicator
State
Description
Table 2.4 – Key Indicators
Key
Indication
Description
PROGRAM
The OIM is in program mode.
MONITOR
The OIM is in monitor mode.
(blank)
The OIM is in a fault, alarm, or diagnostic menu.
FAULT
The Fault Menu is displayed.
ALARM
The Alarm Menu is displayed.
DIAGS
The Diagnostics Menu is displayed.
LOCAL
The drive’s front panel keypad/display is used to
control the drive.
TERMBLK
The signals at the Regulator board terminal strip
are used for control.
OPTION
An option board, such as the AutoMax
Communication Network Option board, is
controlling drive operation. Blinks when the option
board is not communicating on the network.
OIM
The OIM keys control drive operation.