Connection, Configure your kinetix 3 drive, And personal computer – Rockwell Automation Motion Control PTO Application Building Block User Manual
Page 14: Connection on
14
Rockwell Automation Publication CC-QS033A-EN-P - February 2014
Chapter 1 Micro800 Controller PTO Axis Setup
Configure Your Kinetix 3 Drive and Personal Computer Connection
Follow these steps to configure the connection between your personal computer and your drive.
1. Verify your Kinetix 3 drive is Series B with firmware revision 3.005 or later.
Refer to
for examples.
2. Use the keypad on the front of the drive to set the following parameters.
3. Connect the Kinetix 3 drive to your personal computer by using cables shown here.
If you are prompted to install drivers, use the recommended drivers.
4. Verify the COM port number of the 1203-USB adapter in Device Manager on your computer, from the Start menu,
choose Run.
The Run dialog box appears.
5. Type devmgmt.msc in the Open field.
Parameter Name
Parameter
Setting
Drive Address
Pr0.07
248
Serial Port Configuration
Pr0.09
1102
where, 2 - 19,200 Kbps Baud Rate
0 - 8 Data Bits, No Parity, 1 Stop Bit
1 - Modbus-RTU protocol
1 - RS-485
Item
Description
1
Kinetix 3 drive
2
1203-USB converter cable, catalog number 2090-CCMUSDS-48AAxx
3
1203-USB converter
4
USB cable
5
Personal computer with Connected Components Workbench software
5
2
1
3
4