Performance
Specifications
These tables provide performance specifications for the LDC-Series iron core
linear servo motors.
Common Performance Specifications
These performance specifications apply to all LDC-Series iron core linear servo
motors.
Attribute
Value
Motor type
3 phase, wye winding, synchronous permanent magnet
stator, non-ventilated linear motor
Operating speed, max
10 m/s (32.8 ft/s)
Operating voltage, (not for direct connection to AC line)
460V AC rms
Dielectric rating of motor power connections (U,V,W), to ground for 1.0 s
(1)
2500V AC rms 50/60 Hz
Cogging torque
< 5% of the continuous force
Applied bus voltage, max
(2)
650V DC
Electrical cycle length
50 mm (1.9685 in.)
Coil temperature, max
130 °C (266 °F)
Insulation class
130 °C (266 °F) Class B
Thermal time constant, Ref, winding to ambient
45 min
Paint color
Black
(1) Tested during manufacturing process. Do not re-apply test voltage. Contact Application Engineering (631.344.6600) for advice on testing coils post production.