Appendix A Application Programs
SLC Controller Programs (\QuickStart\SLC directory)
File Name
For Use with this Application
Page
dh485.rss
•
Channel 0 must be used on an SLC-5/04 or 5/05
controller with a 1761-NET-AIC Link Coupler
df1.rss
•
SLC 5/03, 5/04, 5/05 controller
•
Channel 0 configured for DF1, no-parity, CRC, and no
handshaking.
•
Baud rate set at 9600
Important: You may need to convert the ladder logic for
the appropriate controller.
dhp.rss
•
SLC 5/04 controller
•
Channel 1 configured for DH+ at 57.6K baud.
dnet.rss
•
SLC 5/02, 5/03, 5/04, 5/05 controller
•
1747-SDN DeviceNet scanner in slot 1
•
Baud rate set at 125K
Important: You may need to convert the ladder logic for
the appropriate controller.
rio.rss
•
SLC 5/02, 5/03, 5/04, 5/05 controller
•
1747-SN scanner in slot 1
•
Baud rate set at 57.6K
Important: You may need to convert the ladder logic for
the appropriate controller.
enet.rss
•
SLC 5/05E (Ethernet) controller
•
IP Address is 10.0.0.1
MicroLogix Controller Programs (\QuickStart\ML directory)
File Name
For Use with this Application
Page
df1.rss
•
MicroLogix 1000 Series C or later controller
Important: You may need to convert the ladder logic for
the appropriate controller.
dh485.rss
•
MicroLogix 1000 Series C or later controller
•
1761-NET-AIC Link Coupler may be needed
•
Channel 0 must be used on an SLC-5/04 or 5/05 with a
1761-NET-AIC Link Coupler
Important: You may need to convert the ladder logic for
the appropriate controller.