Devicenet application tags, Ethernet/ip application tags – Rockwell Automation 2711-ND3 PanelBuilder32 Quick Start Manual User Manual
Page 66

66
Publication 2711-QS003D-EN-P - June 2009
Chapter 5 Entering Application Tags
DeviceNet Application Tags
The table shows application tags used by the DeviceNet application.
Defaults are accepted for fields not shown in table.
EtherNet/IP Application Tags
The table shows application tags used by the ControlLogix controller
in the EtherNet/IP application using controller addressing. Defaults
are accepted for fields not shown in table.
Tag Name
Data Type
Tag
Address
Description
Node
Name
Initial
Value
Min
Max
Start_Motor
Bit
I
:00/0
Starts the motor
LC_1
0
0
0
Stop_Motor
Bit
I
:00/1
Stops the motor
LC_1
0
0
0
Motor_Status_Ind
Bit
O:0/0
Shows on/off motor status
LC_1
0
0
0
Motor_Speed
Unsigned
Integer
O:1
Shows the motor speed
LC_1
0
0
65535
Set_Max_Motor_Speed
Unsigned
Integer
I
:1
Sets the maximum speed
LC_1
1800
600
1800
Speed_Alarm
Bit
O:2/0
Triggers alarm messages
LC_1
0
0
0
Tag Name
Data Type
Tag Address
Description
Node
Name
Initial
Value
Min
Max
Start_Motor
Bit
Motor_Control.00
Starts the motor
LC_1
0
0
0
Stop_Motor
Bit
Motor_Control.01
Stops the motor
LC_1
0
0
0
Motor_Status_Ind
Bit
Motor_Control.02
Shows on/off
motor status
LC_1
0
0
0
Motor_Speed
Signed
Integer/INT
Motor_Speed[0]
Shows the motor
speed
LC_1
0
0
65535
Set_Max_Motor_Speed
Signed
Integer/INT
Motor_Speed[1]
Sets the maximum
speed
LC_1
1800
600
1800
Speed_Alarm
Bit
Alarms.00
Triggers alarm
messages
LC_1
0
0
0