Configuring Your Reader

Publication 2755-6.9

Scanner Setup Commands

Scanner Type. You determine the type of reader you are using.

Entering the command will save the current setting for
Scanner Type to NOVRAM.

Command

Parameter

Format

Example

Scanner Type

0 = Standard

KP

Do not change the reader type.

1 = High Density

KP

Do not change the reader type.

Scans per Second. The scan occurs in 10 millisecond increments.
You can use any number between 30 and 55. The default is 50.

Parameter

Format

Example

KE

To set the reader to 400 scans per
second, press

[]

.

Auto Gain Control. Gain adjustment can be any number from 10
to 255. The default is 45.

Before saving any changes to Gain Adjustment, first record the
optimized factory setting for future reference. Press

[]

to

read factory settings.

Command

Parameter

Format

Example

AGC Sampling

0 = Disabled

To set the gain threshold to 40 and the

1 = Leading Edge

KD

sampling,tracking>

AGC status to Leading Edge, press

[]

2 = Continuous

[]

.

Bad Bar Code Message. You can use any ASCII string up to 7
characters. The default is Bad Code.

Command

Parameter

Format

Example

Status

0 = Disabled

KM

To change the message to “FAULTY”,

[]

1 = Enabled

KM

press

[]

.

No Bar Code Message. You can use any ASCII string up to 7
characters. The default is No Label.

Command

Parameter

Format

Example

Status

0 = Disabled

KN

To change the message to “NO LABEL,

[]

1 = Enabled

KN

press

[]

.

No Object Message. You can use any ASCII string up to 7
characters. The default is Missing.

Command

Parameter

Format

Example

Status

0 = Disabled

KO

To change the message to “VACANT”,

[]

1 = Enabled

KO

press

[].