beautypg.com

Rockwell Automation 2755 AtomScan Bar Code Reader User Manual

Page 75

background image

5–30

Configuring Your Reader

Publication 2755-6.9

Host Port. Changes made in the reader’s communications
parameters such as baud rate, parity, stop bits, LRC, etc., must be
matched in the other device(s) or communications will be lost. If
this occurs, default the reader with the Restore/Save
Default Configuration for Power-on command.

Command

Parameter

Format

Example

Baud Rate

0 = 600

1 = 1200

2 = 2400

3 = 4800

4 = 9600

5 = 19200

6 = 38400

7 = 76800

8 = 300

To change Host Port Baud Rate to 2400,

Parity

Ka

bits,data bits>

To change Host Port Baud Rate to 2400,
press

[]

.

0 = None

[

]

1 = Even

2 = Odd

Stop Bits

0 = One

1 = Two

Data Bits

0 = Seven

1 = Eight