Rockwell Automation 2755 AtomScan Bar Code Reader User Manual
Page 78

5–33
Configuring Your Reader
Publication 2755-6.9
For a sequence on a No Read, refer to the following table. When
disabled, the reader does not sequence (increment or decrement)
on a No Read. When enabled, the reader sequences on every No
Read.
Command
Example
Status
0 = Disabled
If 001, 002, No Read, then search for 003.
1 = Enabled
If 001, 002, No Read, then search for 004.
For a sequence on every mismatch, refer to the following table.
When disabled, if a mismatch is out of sequence by more than 1,
the sequence resumes. When enabled, the reader sequences the
on every mismatch.
Command
Example
Status
0 = Disabled
If 001, 002, 004 (mismatch), then search for 005.
1 = Enabled
If 001, 002, mismatch, then search for 004.
•
New Master Pin
Command
Parameter
Format
Example
Status
0 = Disabled
Kz
To enable New Master Pin, press
[
1 = Enabled
Kz
[
.
•
Number of Labels. You can use any number between 1 and 6.
The default is 1. The multilabel separator is any valid ASCII
character.
Parameter
Format
Example
KL
To change Number of Labels to 3, press
[
.
•
Operations Status Request. Allows you to return the status of
each command in the group.
Parameter
Format
KV
Code Types Commands
•
Narrow Margins
Command
Parameter
Format
Example
Status
0 = Disabled Ko To enable Narrow Margins, press [ 1 = Enabled Ko status,symbology ID [ .
status>