beautypg.com

Rockwell Automation 2755 AtomScan Bar Code Reader User Manual

Page 76

background image

5–31

Configuring Your Reader

Publication 2755-6.9

Auxiliary Port

Command

Parameter

Format

Example

Mode

0 = Disabled

1 = Transparent

2 = Half-duplex

3 = Full-duplex

4 = Slave Mode

Baud Rate

0 = 600

1 = 1200

2 = 2400

3 = 4800

4 = 9600

5 = 19200

To change Auxiliary Port Baud Rate to

6 = 38400

Ky

rate,parity,stop bits,data

To change Auxiliary Port Baud Rate to
2400, press

[]

.

7 = 76800

bits>

[

y

]

8 = 300

Parity

0 = None

1 = Even

2 = Odd

Stop Bits

0 = One

1 = Two

Data Bits

0 = Seven

1 = Eight

Communications Status Request. Allows you to return the status
of each command in the group.

Parameter

Format

KT

Operations Commands

Triggering Mode. The trigger filtering time occurs in 128
microsecond increments. You can use any number between 2 and
255. The default is 78 (approximately 10 seconds).

Command

Parameter

Format

Example

Triggering Mode

0 = Continuous Read

1 = Continuous Read, 1 Output

2 = External Level

Kg

To select External edge, press

[]

3 = External Edge

Kg

time>

[]

.

4 = Serial Data

5 = Serial Data and Edge