Scanner output menu, 5–20 configuring your reader, Scanner output – Rockwell Automation 2755 AtomScan Bar Code Reader User Manual
Page 65

5–20
Configuring Your Reader
Publication 2755-6.9
Scanner Output Menu
The Scanner Output menu, shown below, allows you to configure the
reader’s output. Default settings are in bold type face.
Bar code output data and no read messages are transmitted on pin 2
under conditions set principally in Bar Code Output.
Relay pulses are transmitted via pins 7 and 14 (Relay-1 and Relay-2,
respectively) and individually configured under conditions set in
Relay-1 and Relay-2.
Relay-1 and Relay-2 can allow simultaneous output under
individually programmed conditions.
Output On
–
Mismatch or No Read
–
Match
(or Good Read)
–
Mismatch
–
No Read
Polarity
–
Negative
–
Positive
Pulse Width
(in 10 ms incs)
➀
–
50 ms
–
User Definable
(0 to 255)
Beeper Status
–
On Good
–
On No Read
Beeper Volume
–
Level 4
–
Level 5
–
Off
–
Level 1
–
Level 2
–
Level 3
Full Screens
–
Enabled
–
Disabled
Laser On/Off
–
Disabled
–
Enabled
Scanner Output
Bar Code
Output
–
Good Read
–
Disabled
–
Match
–
Mismatch
When to Output
–
As Soon As
Possible
–
End Of Read
Cycle
No Read Message
7 digits
–
No Read
–
User Definable
(ASCII char.)
No Read Output
–
Enabled
–
Disabled
Relay-1
Relay-2
Partial Output
Length
–
63
–
User Definable
(1 to 63)
Status
–
Disabled
–
Enabled
Start Position
–
1
–
User Definable
(1 to 63)
➀
Divide the number entered on the command line by 100 for time in seconds.