Contactor Ratings
The table below lists the recommended contactor ratings for 8720MC
drives and regenerative power supplies.
Note: For the contactor recommended for use with the
8720MC-RPS190, refer to the 8720MC Regenerative Power Supply
User Manual (publication 8720MC-RM001x-US-P).
AC Line Filter
Specifications
The table below shows the specifications for AC line filters that you
can use with the 8720MC AC drives (8720MC-Bxxx) and regenerative
power supplies (8720MC-RPSxxx).
Catalog Number
Contactor
8720MC-B021
100-C23x10
8720MC-B027
100-C30x10
8720MC-B034
100-C37x10
8720MC-B042
100-C43x10
8720MC-B048
100-C60x10
8720MC-RPS027
100-C30x10
8720MC-RPS065
100-C72x10
8720MC
Component
AC Line Filter
Catalog Number
Specifications
Voltage
Phase
Current
Power
Loss
Weight
Humidity
Vibration
8720MC-RPS027 or
-RPS065
8720MC-RFI80
520V ac
50/60 Hz
Three
80A @ 50° C
(122° F)
25.9W
5.3 kg
(11.7 lb)
90% RH
10-200 Hz
@ 1.8 g
8720MC-RPS190
8720MC-EF190-VB
—
—
—
—
—
—
—
8720MC-B021 or
-B027
1336-RFB-27
460V ac
50/60 Hz
Three
27A @ 50° C
(122° F)
30W
5.0 kg
(11.0 lb)
90% RH
10-200 Hz
@ 1.8 g
8720MC-B034,
-B042, or -B048
1336-RFB-48
460V ac
50/60 Hz
Three
48A @ 50° C
(122° F)
56W
6.0 kg
(13.2 lb)
90% RH
10-200 Hz
@ 1.8 g