Installing Your 8720MC Drive
1-21
When mounting your active shunt module inside the enclosure,
follow these additional guidelines (refer to Figure 1.10 for an
example).
• Metal-clad modules can be mounted anywhere in the dirty zone,
but as close to the 8720MC as possible
• Shunt power wires can be run with motor power cables.
• Separate shunt power cables from other sensitive, low voltage
signal cables.
Figure 1.10
External Active Shunt Inside the Enclosure
C
C
D
VD
D
P1
P4
P5
TB1
BULLETIN 1336 BRAKING CHOPPER
FOR USE WITH
460 VAC A.F. DRIVES
CAT
1336-WB009 SER A
INPUT
750 VDC 9.0 ADC (RMS)
MADE IN U.S.A.
DC POWER
BRAKE ON
UL
®
LIS
TED 966X
IND
CONT E
Q
UL
®
LIS
TED 966X
IND
CONT E
Q
C
A
–
B P\N 74101-778-XX REV
VD
Dirty Wireway
Clean Wireway
Enclosure
Twisted conductors
(2 twists per foot) min. or
a shielded twisted pair.
Shield Clamp(s)
Route 24V dc I/O
Shielded Cable
Route Encoder/Analog/Registration
Shielded Cable
Motor Power
Shielded Cable
AC
Line Filter
8720MC
B Frame Chassis
Shield
Clamps
Note: Input AC components not
included in this figure.
Keep very dirty connections
as short as possible and
segregated (not in wireway)
150 mm (6.0 in.) of
clearance on all sides
of the shunt module
minimum
Allen-Bradley
Bulletin 1336-MOD-KBxxx
External Active Shunt Module