Wiring your 8720mc, Power wiring requirements, Ac drive power wiring requirements – Rockwell Automation 8720MC High Performance Drives Installation Manual User Manual
Page 76: Wiring your 8720mc -14, Power wiring requirements -14, Ac drive power wiring requirements -14

Publication 8720MC-IN001D-EN-P — December 2002
3-14
Connecting Your 8720MC
Wiring Your 8720MC
The following sections provide information and procedures on how to
wire your 8720MC. These procedures assume you have mounted your
8720MC components, bonded them to the subpanel, and have no
power applied to the system.
Power Wiring Requirements
Power wiring requirements are given in the tables below. Wire should
be copper with 75
° C (167° F) minimum rating. Phasing of main AC
power is arbitrary and earth ground connection is required for safe
and proper operation. Input drive power is either AC or DC
depending on your drive type and application. For additional
information refer to Power Specifications in Appendix A. Refer to
Appendix B for the 8720MC interconnect diagrams.
AC Drive Power Wiring Requirements
8720MC Drive
Description
Connects to
Terminals
Recommended
Wire Size
mm
2
(AWG)
Torque Value
Nm (lb-in.)
TB1
8720MC-B021 and -B027
B frame
AC Input Power
6 (10)
1.70 (15)
R (L1), S (L2),
T (L3)
Motor Power
Motor
power
cable depends on
motor/drive
combination.
U (T1), V (T2),
W (T3)
8720MC-B034 B frame
AC Input Power
10 (8)
R (L1), S (L2),
T (L3)
Motor Power
Motor
power
cable depends on
motor/drive
combination.
U (T1), V (T2),
W (T3)
8720MC-B042 and -B048
B frame
AC Input Power
16 (6)
5.65 (50)
R (L1), S (L2),
T (L3)
Motor Power
Motor
power
cable depends on
motor/drive
combination.
U (T1), V (T2),
W (T3)