P4 connector pin-out (analog), P5 connector pin-out (analog) – Rockwell Automation 8720MC High Performance Drives Installation Manual User Manual
Page 41
Publication 8720MC-IN001D-EN-P — December 2002
8720MC Connector Data
2-7
P4 Connector Pin-out (Analog)
The following table provides the signal descriptions and pin-out for
the Weidmueller double row 5.00 mm (P4) connector. Refer to Figure
2.5 for connector pin locations.
P5 Connector Pin-out (Analog)
The following table provides the signal descriptions and pin-out for
the Weidmueller double row 5.00 mm (P5) connector. Refer to Figure
2.5 for connector pin locations.
P4 Pin
Description
Signal
P4 Pin
Description
Signal
1
Analog Output 1
ANAOUT_CH1
5
Analog Output 2
ANAOUT_CH2
2
+5V dc Registration Input
REG2
6
Analog Output Common
ANA_COM
3
+24V dc Registration Input
REG1
7
Registration Common
REG_COM
4
+5V dc Power for Registration Input
REG_5V
8
+5V dc Registration Power Return
REG_5VCOM
P5 Pin
Description
Signal
P5 Pin
Description
Signal
1
A quad B: A+ Channel Output
AMOUT+
19
A quad B: A Channel Output
AMOUT-
2
A quad B: B+ Channel Output
BMOUT+
20
A quad B: B Channel Output
BMOUT-
3
A quad B: Z+ Channel Output
ZMOUT+
21
A quad B: Z Channel Output
ZMOUT-
4
A quad B common
ACOM
22
8720MC +24V dc power for inputs
IOPWR
5
Reserved
—
23
8720MC +24V dc input power return
REGCOM
6
Drive OK
Relay 1
24
Hi Winding Select
Relay 3
7
25
8
Enable Brake Solenoid
Relay 2
26
Lo Winding Select
Relay 4
9
27
10
Zero Speed
Output 5
28
Orient Complete
Output 6
11
Shut Down Fault
Output 7
29
Torque
≥ Torque Limit
Output 8
12
Auto Reference Enabled
Output 9
30
At Speed
Output 10
13
+24V dc Digital Input common
IOCOM
31
External +24V dc for Digital Outputs
EXTIOPWR
14
Drive Enable
Input 1
32
Orient Request
Input 2
15
Drive Error Reset
Input 3
33
Auto/Manual Select
Input 4
16
Parameter set bit 2 (high/low)
Input 5
34
Jog
Input 6
17
Parameter set bit 1
Input 7
35
Reserved
—
18
Parameter set bit 0
Input 9
36
Regen PS - OK
Input 10
IMPORTANT
To meet CE requirements, motor power and
feedback cable lengths must not exceed 90 m (295.2
ft).