Rockwell Automation 6008-SI IBM PC I/O SCNNR 6008-SI User Manual
Page 24

Chapter 3
Installation
3-6
The factory sets the switches for memory address C000(hex) for an IBM
PC AT or other machine with a 16-bit bus. If you’re running on a PC XT
or another 8-bit bus machine, or if you want to configure the scanner at an
address other than C000(hex), you’ll have to change the switches.
First set switches 7 through 10 to all closed for a PC AT or similar, all open
for a PC XT or similar. The factory setting is all closed, for a PC AT or
other machine with a 16-bit bus.
Next set switches 1 through 6 for the memory address you selected.
Table 3.C shows the correct setting of switches 1 through 6, in that order,
for every hex address below F000, where
O
is an open switch and
c
is a
closed switch:
Table 3.C
Dip Switch Settings for Memory Address (Switches 1 through 6)
Hex
Address
Switch
Setting
Hex
Address
Switch
Setting
Hex
Address
Switch
Setting
0400
Occ ccc
5000
ccO cOc
A000
ccc OcO
0800
cOc ccc
5400
OcO cOc
A400
Occ OcO
0C00
OOc ccc
5800
cOO cOc
A800
cOc OcO
1000
ccO ccc
5C00
OOO cOc
AC00
OOc OcO
1400
OcO ccc
6000
ccc OOc
B000
ccO OcO
1800
cOO ccc
6400
Occ OOc
B400
OcO OcO
1C00
OOO ccc
6800
cOc OOc
B800
cOO OcO
2000
ccc Occ
6C00
OOc OOc
BC00
OOO OcO
2400
Occ Occ
7000
ccO OOc
C000
ccc cOO
2800
cOc Occ
7400
OcO OOc
C400
Occ cOO
2C00
OOc Occ
7800
cOO OOc
C800
1
cOc cOO
3000
ccO Occ
7C00
OOO OOc
CC00
OOc cOO
3400
OcO Occ
8000
ccc ccO
D000
ccO cOO
3800
cOO Occ
8400
Occ ccO
D400
OcO cOO
3C00
OOO Occ
8800
cOc ccO
D800
2
cOO cOO
4000
ccc cOc
8C00
OOc ccO
DC00
OOO cOO
4400
Occ cOc
9000
ccO ccO
E000
ccc OOO
4800
cOc cOc
9400
OcO ccO
E400
Occ OOO
4C00
OOc cOc
9800
cOO ccO
E800
cOc OOO
9C00
OOO ccO
EC00
OOc OOO
1
Not available for the IBM PC XT
2
Recommended for IBM PC AT computers with EGA and VGA graphics