The procedure of installing the scanner board in the host has three main
steps:

1.

Set the scanner board switch block for the memory address you
selected earlier.

2.

Plug the scanner into a slot in the host computer.

3.

Connect the I/O cable to the scanner.

In this section we’ll look at those steps in detail.

Switch Settings

The scanner board has one block of ten DIP switches to be set at
installation time.

Figure 3.2

Dip Switch Location on Scanner Board

Switches

Set switches 1-6 set for RAM address.

(photo shows switches set for PC/AT)

(photo shows switches set for RAM address C4000)

off

on (Close)

(Open)

Set switches 7Ć10 open for PC/XT (6120)

Set switches 7Ć10 closed for PC/AT (TĆ50, 6121, 6122)