Chapter 2
Parameter Option
2–6
IMPORTANT: If you are making more than one parameter change, it is not
necessary to save every new parameter value at the time you make a value
change. All parameter changes can be saved at one time using the
EE/BRAM option detailed in Chapter 4.
In addition to accessing parameters one–by–one in the Linear Parameter
mode, it is also possible to access parameters that have been grouped in
special Files. The number of Files will vary depending on what type of
Drive or Device you are using with the GPT, and how the Drive or Device is
configured. For Example; a 1336 FORCE Drive equipped with a PLC
Communication Adapter Board would have all parameters broken down into
four files which include:
1. Startup File
2. Communication IO File
3. Velocity Torque File
4. Diagnostics File
If you are in the Linear Parameter Mode, press the
F4
soft
designator key to to reach the File/Group/Element Mode (Fig. 2–11).
Figure 2.11
File/Group/Element Initial Screen
File
Group
Parameter:
Lin_Mode
F1
F2
F4
Stall Delay
<
Absolute Overspd
>
VP Warn/None Cfg
VP Flt/Warn Cfg
File
F3
Drive Data
Drive Tune
Limits
Fault Setup
Grp
To access the File options, press the
F1
soft designator key. The
four available File choices will appear as in Figure 2.12.
Accessing the FGE Mode
File Selection