Viewing option module diagnostic items – Rockwell Automation 20-750-CNETC PowerFlex Coaxial ControlNet Option Module User Manual

Page 92

background image

92

Rockwell Automation Publication 750COM-UM003B-EN-P - November 2012

Chapter 7

Troubleshooting

Viewing Option Module
Diagnostic Items

If you encounter unexpected communication problems, the option module’s
diagnostic items may help you or Rockwell Automation personnel troubleshoot
the problem. Option module diagnostic items can be viewed with any of these
drive configuration tools:

PowerFlex 20-HIM-A6 or 20-HIM-C6S HIM

Connected Components Workbench software, version 1.02 or later

DriveExplorer software, version 6.01 or later

DriveExecutive software, version 5.01 or later

For details on viewing diagnostic items using the HIM, see the PowerFlex 20-
HIM-A6/-C6S HIM (Human Interface Module) User Manual, publication

20HIM-UM001

.

Table 11 - Option Module Diagnostic Items

No.

Name

Description

1

Common Logic Cmd

The present value of the Common Logic Command being transmitted to the drive by this option module.

2

Prod Logic Cmd

The present value of the Product Logic Command being transmitted to the drive by this option module.

3

Reference

The present value of the Reference being transmitted to the drive by this option module.

4

Common Logic Sts

The present value of the Common Logic Status being received from the drive by this option module.

5

Prod Logic Sts

The present value of the Product Logic Status being received from the drive by this option module.

6

Feedback

The present value of the Feedback being received from the drive by this option module.

7

Input Size

The size of the input image in bytes transferred from the network to the drive.

8

Output Size

The size of the output image in bytes transferred from the drive to the network.

9

DL Fr Net Avail

The number of Host DL From Net xx Datalinks currently available to the option module.

10

DL To Net Avail

The number of Host DL To Net xx Datalinks currently available to the option module

11

DL Fr Net 01 Val

The present value of respective Host DL From Net xx parameter being transmitted to the drive by this
option module. (If not using a Datalink, its respective value should be zero.)

12

DL Fr Net 02 Val

13

DL Fr Net 03 Val

14

DL Fr Net 04 Val

15

DL Fr Net 05 Val

16

DL Fr Net 06 Val

17

DL Fr Net 07 Val

18

DL Fr Net 08 Val

19

DL Fr Net 09 Val

20

DL Fr Net 10 Val

21

DL Fr Net 11 Val

22

DL Fr Net 12 Val

23

DL Fr Net 13 Val

24

DL Fr Net 14 Val

25

DL Fr Net 15 Val

26

DL Fr Net 16 Val