Technical specifications

Table 15 - Data sheet SC300

–

Applies to the voltage range between U

V

and 0 V.

—

Switching currents

≤500 mA are allowed briefly (100 ms).

˜

In the case of a fault (0V cable open circuit) the maximum leakage current flowing in the OSSD cable. The
downstream controller must detect this status as LOW. A safe PLC (Programmable Logic Controller) must be
able to identify this status.

™

Make sure to limit the individual cable resistance to the downstream controller to this value to ensure that a
cross-circuit between the outputs is safely detected. (Also note EN 60

204 Electrical Machine Equipment, Part 1:

General Requirements.)

š

When active, the outputs are tested cyclically (brief LOW). When selecting the downstream controllers, make
sure that the test pulses do not result in deactivation when using the above parameters.

Minimum

Typical

Maximum

Reset/restart input (RESTART)

Resistance HIGH

2 k

Ω

Capacitance

15 nF

Voltage (IEC 61

131­2)

HIGH

11 V

24 V

30 V

LOW

–3 V

0 V

5 V

Static current

6 mA

15 mA

Actuating time control switch input

120 ms

Teach-in/synchronization (TEACH/SYNCH) input

The input must be operated by a key-operated switch
(contact).

Resistance HIGH

2 k

Ω

Capacitance

15 nF

Voltage HIGH

11 V

24 V

30 V

Static current

6 mA

15 mA

Output signal switching devices (OSSDs)

2 PNP semiconductors, short-circuit protected

–, cross-circuit

monitored

Switching voltage HIGH (active, U

rms

) at 250 mA

V

S

– 2.7 V

V

S

Switching voltage LOW (inactive)

0 V

0 V

3.5 V

Source switching current

6 mA

250 mA

—

Leakage current

˜

250

μA

Load inductance

2.2 H

Load capacity at 50

W

2.2

μF

Permissible line resistance between device and load

™

2.5

Ω

Test pulse date

š

Test pulse width

230

μs

300

μs

Test frequency

120 ms

Response time

20 ms

Switch off time

100 ms

Power-up delay of the OSSDs from red to green

30 ms

Contactors

Permissible dropout time

300 ms

Permissible pick-up time

300 ms