beautypg.com

Rockwell Automation 442L SC300 Safety Sensor User Manual User Manual

Page 43

background image

Rockwell Automation Publication 10000202762 Ver 00 - January 2012

41

Chapter 8

Configuration

Start the teach-in process as follows:

Table 11 - Starting the teach­in process

The SC300 now teaches-in the current configuration and shape of the protective field.
The process takes approx. 15 seconds. During the teach-in the flashing diagnostics LEDs
indicate the configuration detected:

Table 12 - Meaning of the diagnostics LEDs during teach-in

Using the LEDs, check whether the teach-in was successful:

Table 13 - LED displays after teach-in

After teach-in it is imperative you check the protective field (see “Tests of the protective
device by a specialist or authorized personnel” on page 38).

If the teach-in fails:
Check and rectify as necessary the following causes:

– Is the reflector fitted and clean?
– Is the reflector perpendicular to the area of the protective field?
– Is the reflective tape or are sub-segments of the tape very short?

Using the internal teach-in key

Using the key-operated pushbutton for teach-in

Actuate the internal teach-in key using the teach-in pin as
follows:

Actuate for approx. 5 s

(the diagnostics LED 4

flashes 5 times).

If the SC300 does not react, the internal teach-in key is
probably locked. Start the teach-in process using the
key-operated pushbutton for teach-in or unlock the
teach-in key (see “Locking the internal teach-in key” on
page 43).
Release for approx. 2 seconds

(the diagnostics LED 4

flashes 2 times).

Actuate for approx. 5 s

(the diagnostics LED 4

flashes 5 times).

Important: Now remove your hand from the
protective field so that the SC300 can completely detect
the protective field.

Press the external key-operated pushbutton for teach-
in for at least 0.5 seconds.
The diagnostics LED 4

G illuminates.

Release the key-operated pushbutton for teach-in.
The diagnostics LED 4

goes off.

Display

Meaning

1

OSSDs detected and OK

2

External device monitoring (EDM) detected and activated

3

Reset button detected and restart interlock activated

4

Internal teach-in key unlocked

Status LEDs

Diagnostics LEDs

Meaning

1

2

3

4

G

Teach-in was successful. If the protective field is clear and the restart
interlock is deactivated, the SC300
switches to green.

G

Teach-in was successful. If the protective field is clear and restart interlock
is activated, the SC300
waits until the reset button is operated.

G G

Teach-in has failed (for measures see below).