Table 15 - Data sheet SC300
Minimum
Typical
Maximum
General system data
Protective field dimensions
See “Checking the dimensions of the protective field” on page 15.
Type
SC300 safety camera
3 (EN 61
4961, IEC/TR 61 4964)
Safety integrity level
SC300 safety camera
SIL2 (IEC 61 508), SILCL2 (EN 62 061)
Category
SC300 safety camera
3 (EN ISO 13
8491)
Performance Level (Safety integrity level)
SC300 safety camera
PL d (EN ISO 13
8491)
Test rate
50 ¹/
s
(EN ISO 13
8491)
Demand rate
30 ¹/
min
(EN ISO 13
8491)
PFHd (mean probability of a dangerous
failure per hour)
3.2 × 10
–9
T
M
(mission time)
20 years (EN ISO 13
849)
Protection class
III (EN 50
178)
Enclosure rating
IP 54 (EN 60
529)
Resolution
20 mm, 24 mm or 30 mm
Field of view
103° ± 3°
Ambient operating temperature
0 °C
+50 °C
Storage temperature
–25 °C
+70 °C (
≤24 h)
Humidity, taking into account the
operating temperature range
EN 61
4961, section 5.1.2 and section 5.4.2 as well as IEC/TR 61 4964,
section 5.4.2
Air humidity (non-dewing)
15
%
95
%
Sinusoidal vibration
5 g, 10–55 Hz (EN 60
06826)
Shock resistance
10 g, 16 ms (EN 60
068227)
Lighting
Wavelength
850 nm
Occular safety
Photobiologically harmless (IEC 62
4717)