Rockwell Automation 20-COMM-H RS485 HVAC Adapter FRN 2.xxx User Manual
Page 60

6-4
Using Siemens Building Technologies P1 FLN
20-COMM-H RS-485 HVAC Adapter User Manual
Publication 20COMM-UM009D-EN-P
Ta
b
le 6.B
S
iemens Building T
ec
h
nologies P1 FLN P
o
int List (Continued)
Po
in
t
Number
(1
)
(1)
P
oint
s not
list
ed ar
e not
us
ed in
th
is ap
plic
ation
. P
oin
t n
umbe
rs
that
appea
r in
br
ac
es {
}
ma
y be unb
undled.
Po
in
t
Ty
p
e
(2
)
(2)
F
or
a
de
scr
ipt
ion
of
po
in
t ty
pes
, r
ef
er
to
Ta
bl
e 6.
A
on
pag
e
6-2
. Not
e
th
at
th
e
ou
tput
s and input
s ar
e fr
om th
e
ne
tw
or
k per
spe
ct
iv
e,
n
ot t
he dr
iv
e per
spec
tiv
e.
F
or e
xample
, an LA
O
is an out
pu
t fr
om th
e
cont
ro
ller
on
th
e n
et
w
or
k,
b
ut i
t i
s
an
in
pu
t to
th
e
dr
iv
e.
Des
criptor
Englis
h
Units
S
lo
pe
Inte
rc
ep
t
O
N T
ex
t
OFF
T
ex
t
De
fault
R
ang
e
CO
V
(3
)
(3)
CO
V
ind
ic
at
es
whet
he
r
th
e p
oint
s is
ab
le
to
sup
por
t C
O
Vs
and
o
ver
ri
des
.
Desc
ri
ption
{46
}
LA
I
D
LNK A2 OUT
1
0
0
0
– 32
767
Ye
s
B
its
0-1
4 of
Da
tali
nk Out
A2.
{48
}
LA
I
D
LNK B1 OUT
1
0
0
0
– 32
767
Ye
s
B
its
0-1
4 of
Da
tali
nk Out
B1.
{50
}
LA
I
D
LNK B2 OUT
1
0
0
0
– 32
767
Ye
s
B
its
0-1
4 of
Da
tali
nk Out
B2.
{52
}
LA
I
D
LNK C1 OUT
1
0
0
0
– 32
767
Ye
s
B
its
0-1
4 of
Da
tali
nk Out
C1
.
{54
}
LA
I
D
LNK C2 OUT
1
0
0
0
– 32
767
Ye
s
B
its
0-1
4 of
Da
tali
nk Out
C2
.
{56
}
LA
I
D
LNK D1 OUT
1
0
0
0
– 32
767
Ye
s
B
its
0-1
4 of
Da
tali
nk Out
D1
.
{58
}
LA
I
D
LNK D2 OUT
1
0
0
0
– 32
767
Ye
s
B
its
0-1
4 of
Da
tali
nk Out
D2
.
{60
}
LA
I
INPUT REF 1
0.001
-16
.383
0
0
– 32
767
Ye
s
S
ho
ws th
e In
put
Re
fe
re
nce
1 p
arame
ter
.
{61
}
LA
I
INPUT REF 2
0.001
-16
.383
0
0
– 32
767
Ye
s
S
ho
ws th
e In
put
Re
fe
re
nce
2 p
arame
ter
.
{62
}
LA
O
D
LNK A1 I
N
1
0
0
0
– 32
767
Ye
s
B
its
0-1
4 of
Da
tali
nk I
n A1.
{64
}
LA
O
D
LNK A2 I
N
1
0
0
0
– 32
767
Ye
s
B
its
0-1
4 of
Da
tali
nk I
n A2
{66
}
LA
O
D
LNK B1 I
N
1
0
0
0
– 32
767
Ye
s
B
its
0-1
4 of
Da
tali
nk I
n B1.
{68
}
LA
O
D
LNK B2 I
N
1
0
0
0
– 32
767
Ye
s
B
its
0-1
4 of
Da
tali
nk I
n B2.
{70
}
LA
O
D
LNK C1 IN
1
0
0
0
– 32
767
Ye
s
B
its
0-1
4 of
Da
tali
nk I
n C1.
{72
}
LA
O
D
LNK C2 IN
1
0
0
0
– 32
767
Ye
s
B
its
0-1
4 of
Da
tali
nk I
n C2.
{74
}
LA
O
D
LNK D1 IN
1
0
0
0
– 32
767
Ye
s
B
its
0-1
4 of
Da
tali
nk I
n D1.
{76
}
LA
O
D
LNK D2 IN
1
0
0
0
– 32
767
Ye
s
B
its
0-1
4 of
Da
tali
nk I
n D2.
{89
}
LA
O
LOGIC CM
D
LO
1
0
0
0
– 25
5
Ye
s
Lo
wer 8 b
its
of Pro
duc
t Log
ic
Co
mma
nd W
ord.
{90
}
LA
O
LOGIC CM
D
HI
1
0
0
0
– 25
5
Ye
s
High
er 8 b
its
of Prod
uc
t Log
ic
Co
mma
nd W
ord.
{91
}
LA
I
F
EEDBA
CK
1
0
0
0
– 32
767
Ye
s
F
eedb
ac
k v
alue
bits
0-14
(abs
olu
te v
alu
e).
{92
}
LA
O
R
EFERENCE
1
0
0
0
– 32
767
Ye
s
R
ef
erenc
e v
alu
e bi
ts 0
-14.
{93
}
LD
I
O
K.F
A
UL
T
1
0
FA
U
LT
OK
0 (OK)
0
– 1
Ye
s
Sho
w
s if
the
dr
iv
e is
fa
ulte
d or n
ot.
{94}
LD
O
R
ESET F
A
UL
T
1
0
R
ESET
NORMAL
0 (NORMAL)
0
– 1
Yes
Resets
the f
ault condition in t
he
dr
iv
e.
Special point
.
Wil
l retu
rn
to
NORMAL (0
)
auto
m
ati
cal
ly
.
{95
}
LA
I
LOGIC STS LO
1
0
0
0
– 25
5
Ye
s
Lo
wer 8 b
its
of Pro
duc
t Log
ic
Status
W
ord.
{96
}
LA
I
LOGIC STS HI
1
0
0
0
– 25
5
Ye
s
High
er 8 b
its
of Prod
uc
t Log
ic
Status
W
ord.
{99
}
LA
O
E
RR
OR ST
AT
US
1
0
0
0
– 25
5
Ye
s
Not u
sed
b
y t
his
app
lic
atio
n.