Schematic drawings, 98d00705 – Rockwell Automation 23C PowerFlex 400 AC Drive Packages for Fan & Pump Apps User Manual
Page 99

Rockwell Automation Publication 23C-IN001B-EN-P - June 2013
99
3 Contactor Full Feature Bypass with Disconnect Package (Style B/N)
Chapter 2
Schematic Drawings
Figure 68 - 3.0…50 Hp, 208V AC & 3.0…150 Hp, 460V AC Drives (Sheet 1 of 2) - NEMA/UL Type 1
98D00705
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
01
DA
T
E
REV
.
BY
ECN/CR.
NO
.
A
11/24/04
JRF
B
2/3/05
JRF
C
9/13/06
REH
D
6/8/07
REH
E
6/25/08
A
WR
F
1/31/11
JLD
G
4/6/12
JCK
APPR
O
V
AL
DESIGN REVIEW
FOR MANUF
A
CTURING
AS SHIPPED
AS COMMISSIONED
BY
DA
T
E
SH.
NEXT
NO
.
SH.
-
DW
G
.
ENG.
TITLE
CHK.
BY
NO
.
DA
T
E
DA
T
E
DR.
BY
DA
T
E
THIS DRA
WING IS
THE PR
OPER
TY OF R
OCKWELL A
UT
OMA
TION, INC
.
OR ITS SUBSIDIARIES AND MA
Y NO
T BE COPIED
, USED OR DISCLOSED FOR ANY
PURPOSE EXCEPT AS A
UTHORIZED IN
WRITING BY R
OCKWELL A
UT
OMA
TION, INC
.
1
2
SCHEMA
TIC DRA
WING - PF400, STYLE B
3-50HP @ 208V
A
C & 3-150HP @ 460V
A
C
98D00705
JRF/A
CI
4/6/04
JFH/A
CI
4/6/04
ST
A
TS
FREEZE/FIRE
IF INTERLOCK USED
REMO
VE JUMPER
BC
OL
PURGE
DOC
BYP
ASS
A
UT
O ST
AR
T
INTERLOCKS
31
34
37
31
230V
32
1
33
36
35
38
43
42
41
H1
208V
X1
FU4
44
BC
39
40
DRIVE
INPUT
CONT
A
CT
OR
DIC
39
40
460V
115V
A
C
H3
H2
T1
H4
X2
FU5
DS1
MAIN DISCONNECT SWITCH
FU3
FU2
FU1
L23
L22
L21
OL
BC
MO
T
OR
T2
T3
T1
T2
T3
T3
T2
T1
T1
CONN2
REMO
VE JUMPER
IF INTERLOCK USED
C
B
A
2
P1
3
P2
B
A
CP1
CONTR
OL P
ANEL
12
31
16
13
33
32
7
11
35
34
9
8
37
36
4
10
41
38
6
5
43
42
1
14
45
44
3
2
49
48
CONN1
X2
15
BC
45
50
46
DIC
DOC
51
47
BC
OL
BYP
ASS
CONT
A
CT
OR
DRIVE
OUTPUT
CONT
A
CT
OR
X2
DOC
BC
1
61
23
63
62
OPENING OF FREEZE/FIRE INTERLOCK (IN DRIVE
MODE)
WILL REQ
UIRE MANU
AL RESET
.
1
"P2" DEF
A
UL
T POSITION IS P
ARKED IN POSITION
"A-B".
FOR DRIVE
TEST IN BYP
ASS MO
VE "P2"
T
O
POSITION "B-C".
"P1" DEF
A
UL
T POSITION IS P
ARKED IN POSITION
"A".
FOR PURGE.
WITH HAND-OFF-A
UT
O SWITCH IN
OFF POSITION MO
VE "P1"
T
O POSTION "B".
3
2
45
65
64
67
66
67
DOC
63
68
64
DOC
69
65
67
W/T3
DOC
V/T2
U/T1
U
VW
PO
WERFLEX 400
INCOMING
3
f
PO
WER
DM1
SEE SH.2
FOR CONTR
OL P
ANEL SCHEMA
TIC
( )
10V 20MA
RUN/FWD
FUNCTION LOSS
SOFTWARE ENABLE
DIGIT AL INPUT 1 (PURGE)
DIGIT AL COMMON
DIGIT AL INPUT 2 (LOCAL)
DIGIT AL INPUT 3 (CLEAR F
AUL
T)
DIGIT AL COMMON
DIGIT AL INPUT 4 (COMM POR
T)
1
3
24
7
5
6
89
10V 20MA
CONTR
OL BO
ARD
AO
2
10V 20MA
AO
1
AI1
ANALOG COM. #1
ANALOG OUTPUT #2 (OUTPUT CURRENT 0-10V)
ANALOG OUTPUT #1 (FREQUENCY 0-10V)
ANALOG INPUT #1
+ 10VDC
+ 24VDC
ANALOG INPUT #2
#1 RELA Y N.O
. (READ
Y/FA
UL T)
ANALOG COM #2
OPTO OUTPUT (A
T FREQUENCY)
#1 RELA Y COMMON
#1 RELA Y N.C
.
#2 RELA Y N.O
. (MO
TOR R
UNNING)
#2 RELA Y COMMON
#2 RELA Y N.C
.
RJ-45 SHIELD
OPTO COMMON
15
11
10
12
13
14
16
17
19
18
20
R3
R1
R2
R4
R5
R6
SRC
10V 20MA
AI2
SNK
MG
LG
X2
P2
P1
T/L3
DIC
S/L2
R/L1
R
ST
L3
L2
L1
SUPPRESSORS
AS REQ
UIRED