Parameter defaults (style b/n), Parameter defaults, Style b/n) – Rockwell Automation 23C PowerFlex 400 AC Drive Packages for Fan & Pump Apps User Manual
Page 95
Rockwell Automation Publication 23C-IN001B-EN-P - June 2013
95
3 Contactor Full Feature Bypass with Disconnect Package (Style B/N)
Chapter 2
Parameter Defaults
(Style B/N)
Parameter Name
Number
Default
Output Freq
b001
Read Only
Commanded Freq
b002
Read Only
Output Current
b003
Read Only
Output Voltage
b004
Read Only
DC Bus Voltage
b005
Read Only
Drive Status
b006
Read Only
Fault 1 Code
b007
Read Only
Process Display
b008
Read Only
Output Power
b010
Read Only
Elapsed MWh
b011
Read Only
Elapsed Run Time
b012
Read Only
Torque Current
b013
Read Only
Drive Temp
b014
Read Only
Elapsed kWh
b015
Read Only
Motor NP Volts
P031
Drive Rated Volts
Motor NP Hertz
P032
60 Hz
Motor OL Current
P033
Drive Rated Amps
Minimum Freq
P034
0.0 Hz
Maximum Freq
P035
60 Hz
Start Source
P036
6 “2-W Lvl/Enbl”
(1)
Stop Mode
P037
1 “Coast, CF”
Speed Reference
P038
2 “Analog In1”
Accel Time 1
P039
20.00 Secs
Decel Time 1
P040
20.00 Secs
Reset To Defalts
P041
0 “Ready/Idle”
Auto Mode
P042
0 “No Function”
Digital In1 Sel
T051
1 “Purge”
Digital In2 Sel
T052
3 “Local”
Digital In3 Sel
T053
10 “Clear Fault”
Digital In4 Sel
T054
4 “Comm Port”
Relay Out1 Sel
T055
0 “Ready/Fault”
Relay Out1 Level
T056
0.0
Relay 1 On Time
T058
0.0 Secs
Relay 1 Off Time
T059
0.0 Secs
Relay Out2 Sel
T060
2 “MotorRunning”
Relay Out2 Level
T061
0.0
Relay 2 On Time
T063
0.0 Secs
Relay 2 Off Time
T064
0.0 Secs
Opto Out Sel
T065
1 “At Frequency”
Opto Out Level
T066
0.0
Opto Out Logic
T068
0 “Normally Open”
Analog In 1 Sel
T069
2 “0-10V”
Analog In 1 Lo
T070
0.0%
Analog In 1 Hi
T071
100.0%
Analog In 1 Loss
T072
0 “Disabled”
Analog In 2 Sel
T073
1 “4-20 mA”
Analog In 2 Lo
T074
0.0%
Analog In 2 Hi
T075
100.0%
Analog In 2 Loss
T076
0 “Disabled”
Sleep-Wake Sel
T077
0 “Disabled”
Sleep Level
T078
10.0%
Sleep Time
T079
0.0 Secs
Wake Level
T080
15.0%
Wake Time
T081
0.0 Secs
Analog Out1 Sel
T082
0 “OutFreq 0-10”
Analog Out1 High
T083
100%
Analog Out1 Setpt
T084
0.0%
Analog Out2 Sel
T085
1 “OutCurr 0-10”
Analog Out2 High
T086
100%
Analog Out2 Setpt
T087
0.0%
Language
C101
1 “English”
Comm Format
C102
0 “RTU 8-N-1”
Comm Data Rate
C103
3 “9600”
Comm Node Addr
C104
100
Comm Loss Action
C105
0 “Fault”
Comm Loss Time
C106
5.0 Secs
Comm Write Mode
C107
0 “Save”
Purge Frequency
A141
5.0 Hz
Internal Freq
A142
60.00 Hz
Preset Freq 0
A143
0.0 Hz
Preset Freq 1
A144
5.0 Hz
Preset Freq 2
A145
10.0 Hz
Preset Freq 3
A146
20.0 Hz
Accel Time 2
A147
30.00 Secs
Decel Time 2
A148
30.00 Secs
S Curve %
A149
20%
PID Trim Hi
A150
60.0 Hz
PID Trim Lo
A151
0.0 Hz
PID Ref Sel
A152
0 “PID Disabled”
PID Feedback Sel
A153
0 “Analog In 1”
PID Prop Gain
A154
0.01
PID Integ Time
A155
2.0 Secs
PID Diff Rate
A156
0.00
PID Setpoint
A157
0.0%
PID Deadband
A158
0.0%
PID Preload
A159
0.0 Hz
Process Factor
A160
30.0
Auto Rstrt Tries
A163
0
Auto Rstrt Delay
A164
1.0 Secs
Start At PowerUp
A165
1 “Enabled”
Reverse Disable
A166
1 “Rev Disabled”
Flying Start En
A167
1 “Enabled”
PWM Frequency
A168
4.0 kHz
PWM Mode
A169
1 “2-Phase”
Boost Select
A170
4 “45.0, VT”
Start Boost
A171
2.5%
Break Voltage
A172
25.0%
Break Frequency
A173
15.0 Hz
Maximum Voltage
A174
Drive Rated Volts
Slip Hertz @ FLA
A175
2.0 Hz
DC Brake Time
A176
0.0 Secs
DC Brake Level
A177
Drive Rated Amps
DC Brk Time@Strt
A178
0 (Disabled)
Current Limit 1
A179
Drive Rated Amps
Current Limit 2
A180
Drive Rated Amps
Motor OL Select
A181
0 “No Derate”
Drive OL Mode
A182
3 “Both-PWM 1st”
SW Current Trip
A183
0.0 (Disabled)
Load Loss Level
A184
0.0 (Disabled)
Load Loss Time
A185
0 Secs
Stall Fault Time
A186
0 “60 Seconds”
Bus Reg Mode
A187
1 “Enabled”
Skip Frequency 1
A188
0 Hz
Skip Freq Band 1
A189
0.0 Hz
Skip Frequency 2
A190
0 Hz
Skip Freq Band 2
A191
0.0 Hz
Skip Frequency 3
A192
0 Hz
Skip Freq Band 3
A193
0.0 Hz
Compensation
A194
1 “Electrical”
Reset Meters
A195
0 “Ready/Idle”
Testpoint Sel
A196
400
Fault Clear
A197
0 “Ready/Idle”
Program Lock
A198
0 “Unlocked”
Motor NP Poles
A199
4
Relay Out3 Sel
R221
0 “Ready/Fault”
Relay Out3 Level
R222
0.0
Relay Out4 Sel
R224
0 “Ready/Fault”
Relay Out4 Level
R225
0.0
Relay Out5 Sel
R227
0 “Ready/Fault”
Relay Out5 Level
R228
0.0
Relay Out6 Sel
R230
0 “Ready/Fault”
Relay Out6 Level
R231
0.0
Relay Out7 Sel
R233
0 “Ready/Fault”
Relay Out7 Level
R234
0.0
Relay Out8 Sel
R236
0 “Ready/Fault”
Parameter Name
Number
Default
Relay Out8 Level
R237
0.0
Aux Motor Mode
R239
0 “Disabled”
Aux Motor Qty
R240
1 “1 Aux Mtr”
Aux 1 Start Freq
R241
50.0 Hz
Aux 1 Stop Freq
R242
25.0 Hz
Aux 1 Ref Add
R243
0.0%
Aux 2 Start Freq
R244
50.0 Hz
Aux 2 Stop Freq
R245
25.0 Hz
Aux 2 Ref Add
R246
0.0%
Aux 3 Start Freq
R247
50.0 Hz
Aux 3 Stop Freq
R248
25.0 Hz
Aux 3 Ref Add
R249
0.0%
Aux Start Delay
R250
5.0 Secs
Aux Stop Delay
R251
3.0 Secs
Aux Prog Delay
R252
0.50 Secs
Aux AutoSwap Tme
R253
0.0 Hr
Aux AutoSwap Lvl
R254
50.0%
Control Source
d301
Read Only
Contrl In Status
d302
Read Only
Comm Status
d303
Read Only
PID Setpnt Displ
d304
Read Only
Analog In 1
d305
Read Only
Analog In 2
d306
Read Only
Fault 1 Code
d307
Read Only
Fault 2 Code
d308
Read Only
Fault 3 Code
d309
Read Only
Fault 1 Time-hr
d310
Read Only
Fault 1 Time-min
d311
Read Only
Fault 2 Time-hr
d312
Read Only
Fault 2 Time-min
d313
Read Only
Fault 3 Time-hr
d314
Read Only
Fault 3 Time-min
d315
Read Only
Elapsed Time-hr
d316
Read Only
Elapsed Time-min
d317
Read Only
Output Powr Fctr
d318
Read Only
Testpoint Data
d319
Read Only
Control SW Ver
d320
Read Only
Drive Type
d321
Read Only
Output Speed
d322
Read Only
Output RPM
d323
Read Only
Fault Frequency
d324
Read Only
Fault Current
d325
Read Only
Fault Bus Volts
d326
Read Only
Status @ Fault
d327
Read Only
(1)
The default values of these parameters differ from Factory
Defaults. Setting P041 [Reset To Defalts] to 1 “Factory Rset” will
change these parameter settings to the defaults listed in the
PowerFlex 400 User Manual.
Parameter Name
Number
Default
ATTENTION: Parameter
A165 [Start At PowerUp] ships
from the factory enabled. This
feature allows a Run
command to automatically
cause the drive to resume
running at commanded speed
after drive input power is
restored. Equipment damage
and/or personal injury may
result if this parameter is used
in an inappropriate
application. Do not use this
function without considering
applicable local, national and
international codes, standards,
regulations or industry
guidelines.