95d02443, Drive, Purge – Rockwell Automation 23C PowerFlex 400 AC Drive Packages for Fan & Pump Apps User Manual
Page 142: Byp ass ru n test byp ass drive, Trip byp ass
142
Rockwell Automation Publication 23C-IN001B-EN-P - June 2013
Chapter 2
3 Contactor Full Feature Bypass with Disconnect Package (Style B/N)
Figure 111 - 3.0…5.0 Hp, 460V AC Drives - NEMA/UL Type 4
95D02443
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
01
DA
T
E
REV
.
BY
ECN/CR.
NO
.
A
6/22/11
DJK
B
4/4/12
JCK
APPR
O
V
AL
DESIGN REVIEW
FOR MANUF
A
CTURING
AS SHIPPED
AS COMMISSIONED
BY
DA
T
E
SH.
NEXT
NO
.
SH.
-
DW
G
.
ENG.
TITLE
CHK.
BY
NO
.
DA
T
E
DA
T
E
DR.
BY
DA
T
E
THIS DRA
WING IS
THE PR
OPER
TY OF R
OCKWELL A
UT
OMA
TION, INC
.
OR ITS SUBSIDIARIES AND MA
Y NO
T BE COPIED
, USED OR DISCLOSED FOR ANY
PURPOSE EXCEPT AS A
UTHORIZED IN
WRITING BY R
OCKWELL A
UT
OMA
TION, INC
.
1
1
LA
Y
OUT DRA
WING
PF400, FRAME C
, STYLE B
, 3-5HP @ 480V
A
C
NEMA 3R/4, NO A/C
95D02443
ALB/A
CI
7/7/08
FR
ONT VIEW
CB1
L1
L2
L3
CIRCUIT BREAKER
OPTIONAL
INSIDE VIEW
(DOOR NO
T SHO
WN FOR CLARITY)
TB2
TB1
T1
MG
T2
T3
40
39
38
37
36
35
34
33
32
31
MTR GR
OUND
OUTPUT PO
WER
TERMINAL BLOCK
INTERLOCK
OPEN
READ
Y
SEE DRIVE DISPLA
Y
DRIVE
FOR DRIVE ST
A
TUS
OUTPUT
ENABLE
HAND
MO
T
OR
AU
T
O
MO
T
OR
OFF
DOC
DRIVE
DIC
PURGE
DRIVE
BYP
ASS
RU
N
TEST
BYP
ASS
DRIVE
BC
OL
TRIP
BYP
ASS
SPEED
MANU
AL
1
2
3
4
5
6
7
8
9
10
0
P1
BC
DIC
DOC
SA-11
-3
-4
NO
-4
-3
NO
-1
NC
-2
-2
NC
-1
-3
-4
NO
-4
-3
NO
-1
NC
-2
-2
NC
-1
SA-11
SA-11
-3
-4
NO
-4
-3
NO
-1
NC
-2
-2
NC
-1
SA-20
-3
-4
NO
-4
-3
NO
-1
NC
-2
-2
NC
-1
A
C
_V
ND_
LAB
EL
AC
_
P
A
R
T
_
N
O
AC
_
D
E
S
C
R
IP
T
IO
N
DE
VI
CE_
ID
AC
_
C
P
A
RT
_
N
O
AC
_
N
OT
E
F
AS
T
EN
ER
A
C
_S
CAL
E_U
N
IT
AC
_
V
IE
W
_
C
O
D
E
TB2
TB1
32
31
34
33
36
35
38
37
40
39
T1
T3
T2
MG
TB3
TH1
FR
ONT VIEW
GND
DS1
L1
L2
L3
L1
R/
L2
S/
L3
T/
T1
U/
T2
V/
T3
W/
P1
P2
INPUT PO
WER
TERMINAL BLOCK
INSIDE VIEW
(DOOR NO
T SHO
WN FOR CLARITY)
HTR (OPTIONAL)
LR (OPTIONAL)
T
150V
A
PRIMAR
Y
FU4
TA-2-69302
FU5
SECOND
AR
Y
H1
H3
H2
H4
X2
F2
F1
X1
FU8
400
FRAME SIZE C
P
ANEL MOUNT
-RESTRICTED SP
A
CE-
MINIMUM MOUNTING
CLEARANCE ABO
VE
THE DRIVE IS 4.7"
-RESTRICTED SP
A
CE-
MINIMUM MOUNTING
CLEARANCE BELO
W
THE DRIVE IS 4.7"
DM1
PE GR
OUND
SIGNAL
TERMINAL BLOCK
OUTPUT PO
WER
TERMINAL BLOCK
ON
O
F
F
FU3
FU2
FU1
A1
A2
1L
1
3
L
2
5
L
3
1
3
N
O
A
2T
1
4
T
2
6
T
3
1
4
N
O
A1
A2
1L
1
3
L
2
5
L
3
1
3
N
O
A
2T
1
4
T
2
6
T
3
1
4
N
O
A1
A2
1L
1
3
L
2
5
L
3
1
3
N
O
A
2T
1
4
T
2
6
T
3
1
4
N
O