97d01548, Main disconnect switch, Ds1 or cb1 – Rockwell Automation 23C PowerFlex 400 AC Drive Packages for Fan & Pump Apps User Manual
Page 31: Cust omer connections
![background image](/manuals/577252/31/background.png)
Rockwell Automation Publication 23C-IN001B-EN-P - June 2013
31
Main Input Disconnect Package (Style A/M)
Chapter 1
Figure 12 - 3.0…50 Hp, 208V AC & 3.0…150 Hp, 460V AC Drives - NEMA/UL Type 12, 4, & 3R
97D01548
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
01
DA
T
E
REV
.
BY
ECN/CR.
NO
.
A
11/14/06
REH
B
4/11/12
JCK
APPR
O
V
AL
DESIGN REVIEW
FOR MANUF
A
CTURING
AS SHIPPED
AS COMMISSIONED
BY
DA
T
E
SH.
NEXT
NO
.
SH.
-
DW
G
.
ENG.
TITLE
CHK.
BY
NO
.
DA
T
E
DA
T
E
DR.
BY
DA
T
E
THIS DRA
WING IS
THE PR
OPER
TY OF R
OCKWELL A
UT
OMA
TION, INC
.
OR ITS SUBSIDIARIES AND MA
Y NO
T BE COPIED
, USED OR DISCLOSED FOR ANY
PURPOSE EXCEPT AS A
UTHORIZED IN
WRITING BY R
OCKWELL A
UT
OMA
TION, INC
.
1
1
INTER-CONNECT DRA
WING - PF400, STYLE A
3-50HP @ 208V
A
C
, 3-150HP @ 460V
A
C
NEMA 3R, 4, 12
97D01548
JFH/A
CI
11/23/05
JCL/A
CI
02/17/06
JFH/A
CI
11/23/06
INCOMING
3
f
PO
WER
MAIN
DISCONNECT
SWITCH
GR
OUND
CONNECTIONS SUPPLIED BY CUST
OMER
OPENING OF
THE FREEZE/FIRE INTERLOCK
WILL REQ
UIRE MANU
AL RESET
.
1
10
OPTO COMMON
AU
T
O
DIGIT AL INPUT 4 (COMM POR
T)
DIGIT AL COMMON
DIGIT AL INPUT 3 (CLEAR F
AUL
T)
DIGIT AL INPUT 2 (ANALOG 1 IN)
DIGIT AL COMMON
DIGIT AL INPUT 1 (PURGE)
SOFTWARE ENABLE
FUNCTION LOSS
S
TAT
S
FREEZE/FIRE
A
UT
O ST
AR
T
INTERLOCKS
1
RUN/FWD
3
24
PURGE
HAND
57
6
89
10V 20MA
AO
1
AO
2
10V 20MA
CONTR
OL BO
ARD
S/L2
T/L3
R/L1
P2
P1
RJ-45 SHIELD
#2 RELA Y N.C
.
#2 RELA Y COMMON
#2 RELA Y N.O
. (MO
TOR R
UNNING)
#1 RELA Y N.C
.
#1 RELA Y COMMON
OPTO OUTPUT (A
T FREQUENCY)
ANALOG COM #2
#1 RELA Y N.O
. (READ
Y/FA
UL T)
ANALOG INPUT #2
ANALOG OUTPUT #2 (OUTPUT CURRENT 0-10V)
ANALOG OUTPUT #1 (FREQUENCY 0-10V)
ANALOG COM. #1
ANALOG INPUT #1
R1
1
SPEED REF
. INPUT
4-20MA, 250 OHM
INPUT IMPED
ANCE
+
+ 24VDC
+ 10VDC
11
12
14
13
15
17
16
18
20
19
R4
R2
R3
R5
R6
10V 20MA
10V 20MA
AI1
SNK
AI2
SRC
PO
WERFLEX 400
W/T3
V/T2
U/T1
2
2
WHEN IN "A
UT
O MODE" SPEED REFERENCE
WILL
COME FR
OM 4-20ma SOURCE
WIRED
T
O ANALOG
INPUT #2.
IF 0-10V SOURCE IS
T
O BE USED
,
CHANGE
P
ARAMETER T73 T
O
"2" V
OL
T
A
GE
MODE
AND
SET DIP SWITCH "AI2"
T
O 10V
.
DM1
DS1
or
CB1
3
4
IF FREEZE/FIRE ST
A
US INTERLOCK IS USED
,
THE
JUMPER
WIRE FR
OM
TERMINALS 1
T
O 3 MUST BE REMO
VED
.
3
IF
THE INTERLOCK CONT
A
CT IS USED
,
THE JUMPER
FR
OM
TERMINALS 1
T
O 3 MUST BE REMO
VED AND
THE JUMPER
WIRE FR
OM
TERMINALS 3
T
O 11 SHOULD
4
BE RELOCA
TED
T
O CONNECT
TERMINALS 1
T
O 11.
34
35
CUST
OMER CONNECTIONS
AUT
O ST AR
T
T3
T2
T1
MO
T
OR
TB
34
35
OFF
X
X
X
L3
L2
L1
GND
PE