95d01571, X2 30 g – Rockwell Automation 23C PowerFlex 400 AC Drive Packages for Fan & Pump Apps User Manual

Page 144

background image

144

Rockwell Automation Publication 23C-IN001B-EN-P - June 2013

Chapter 2

3 Contactor Full Feature Bypass with Disconnect Package (Style B/N)

Figure 113 - 15…20 Hp, 208V AC & 25…40 Hp, 460V AC Drives - NEMA/UL Type 4

95D01571

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

01

DA

T

E

REV

.

BY

ECN/CR.

NO

.

A

2/3/06

REH

B

8/3/06

JCL

C

11/15/06

REH

D

12/22/06

REH

E

7/9/08

ALB

F

6/23/11

DJK

APPR

O

V

AL

DESIGN REVIEW

FOR MANUF

A

CTURING

AS SHIPPED

AS COMMISSIONED

BY

DA

T

E

SH.

NEXT

NO

.

SH.

-

DW

G

.

ENG.

TITLE

CHK.

BY

NO

.

DA

T

E

DA

T

E

DR.

BY

DA

T

E

THIS DRA

WING IS

THE PR

OPER

TY OF R

OCKWELL A

UT

OMA

TION, INC

.

OR ITS SUBSIDIARIES AND MA

Y NO

T BE COPIED

, USED OR DISCLOSED FOR ANY

PURPOSE EXCEPT AS A

UTHORIZED IN

WRITING BY R

OCKWELL A

UT

OMA

TION, INC

.

1

1

LA

Y

OUT DRA

WING

PF400, FRAME D

, STYLE B

, 15-20HP @ 208V

A

C

, 25-40HP @ 480V

NEMA 4

95D01571

REH/A

CI

11/18/05

JCL/A

CI

2/17/06

JFH/A

CI

11/18/06

OPTIONAL CIRCUIT BREAKER

L1

L2

L3

CB1

INPUT PO

WER

TERMINAL BLOCK

INSIDE VIEW

FR

ONT VIEW

LR (OPTIONAL)

ON

OFF

TH1

GND

DS1

L2

L1

L3

FU3

FU2

FU1

ALLEN-BRADLEY

194R-NJ100P3

SIGNAL

TERMINAL

OUTPUT PO

WER

TERMINAL BLOCK

L1

R/

L2

S/

L3

T/

T1

U/

T2

V/

T3

W/

P1

P2

DC-

BLOCK

TB1

TB2

T1

T2

T3

31

32

33

34

35

36

37

38

39

40

MG

PO

WER OUTPUT

TERMINAL BLOCK

MTR GR

OUND

33
32
31

37

35

36

34

40

38

39

TB2

TB1

32
31

34
33

36
35

38
37

40
39

T2

MG

T1

T3

DOOR NO

T SHO

WN FOR CLARITY

INTERLOCK

OPEN

READ

Y

SEE DRIVE DISPLA

Y

DRIVE

FOR DRIVE ST

A

TUS

OUTPUT

ENABLE

HAND

MO

T

OR

AU

T

O

MO

T

OR

OFF

DOC

DRIVE

DIC

PURGE

DRIVE

BYP

ASS

RU

N

TEST

BYP

ASS

DRIVE

BC

OL

TRIP

BYP

ASS

SPEED

MANU

AL

1

2

3

4

5

6

7

8

9

10

0

P1

FU6

HTR (OPTIONAL)

FU7

FU8

BC

DIC

DOC

OL

1

L1

3

L2

5

L3

2

T1

4

T2

6

T3

-3

-4

NO

-4

-3

NO

-1

NC

-2

-2

NC

-1

-3

-4

NO

-4

-3

NO

-1

NC

-2

-2

NC

-1

1

L1

3

L2

5

L3

2

T1

4

T2

6

T3

-3

-4

NO

-4

-3

NO

-1

NC

-2

-2

NC

-1

2

T1

4

T2

6

T3

1

L1

3

L2

5

L3

-3

-4

NO

-4

-3

NO

-1

NC

-2

-2

NC

-1

-3

-4

NO

-4

-3

NO

-1

NC

-2

-2

NC

-1

FU7

X2
30

G

PWR

A/C

T

H1

H3

H2

H5

X2

F2

F1

X1

TA-2-54525

PRIMAR

Y

FU5

FU4

1500V

A

SECOND

AR

Y

H4

A/C PWR

X2
30

G

400