Onfiguration, Xamples, Setting a wi-mod-945-e to factory default settings – Weidmuller WI-MOD-945-E: 900Mhz Wireless Ethernet & Device Server v2.16 User Manual
Page 74: Extending a wired network, 24 - configuration examples
Weidmuller Wireless Ethernet Modem & Device Server WI-MOD-945-E User Manual
Page 74
www.weidmuller.com
Rev 2.136
3.24 - Configuration Examples
Setting a WI-MOD-945-E to Factory Default Settings
Access configuration webpages on the WI-MOD-945-E. Refer section
”3.2 - ”Configuring the Unit for the first time”.
Click on
“System Tools” Menu Item
Click on Factory Default Configuration Reset, and wait for unit to reset. While the module executes the reset
sequence the OK LED will flash. The OK LED will turn green when the reset sequence is complete.
Extending a wired network
Access Point Configuration
Connect straight through Ethernet cable between PC and WI-MOD-945-E.
Ensure configuration PC and WI-MOD-945-E are setup to communicate on the same network
Set dipswitch to SETUP mode.
Power up unit, and wait for the OK LED to cease flashing.
Adjust PC network settings
Set Configuration PC network card with network setting of IP address 192.168.0.1, netmask 255.255.255.0
Open configuration webpage with Internet Explorer at address 192.168.0.1XX/ where XX is the last two digits of the
module’s serial number
When prompted for password, enter default username “user” and password “user”
Click
“Network”, and select Operating Mode as Access Point.
Select Device Mode as Bridge.
Change the Gateway IP Address to 192.168.0.1
Change the Ethernet and Wireless IP addresses to 192.168.0.200
Change Ethernet and Wireless Subnet masks to 255.255.255.0
Enter a System Address (ESSID) string
Select the Radio Encryption required.
Set dipswitch to RUN
Save the changes and unit will restart with new settings.
Client 1 Configuration
Perform the same configuration steps as the Access Point configuration with the following differences:
Set the Ethernet and Wireless IP addresses of WI-MOD-945-E to 192.168.0.201
Set the Operating Mode to Client.
Figure 57 - Example Config 1