Motion features, Motionless timeout, In references – Wasp Barcode WDI4600 2D Product Reference Guide User Manual
Page 246: Otion, Eatures
![background image](/manuals/575383/246/background.png)
References
236
WDI4600
Motion Features
Motionless Timeout
This setting specifies the amount of time that the reader takes to assume that it is in a motionless
condition. The range for this setting is from 500 msec to 25.5 seconds, in 100 millisecond
increments.
Follow these instructions to set this feature.
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0.5 = 0005 = 00, 5 =
050, 20 = 200, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE barcode to
enter Programming Mode.
4. Scan the barcode: SELECT MOTIONLESS TIMEOUT SETTING.
5. Scan the appropriate three digits from the keypad in
representing
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the begin-
ning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
Mode.
This completes the procedure. See
for examples of how to set this feature.
Table 45. Motionless Timeout Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
500ms
1 sec.
10 sec
9,900ms (9.9 sec.)
2
Divide by 100 (and pad with
leading zeroes to yield two
digits)
005
010
100
250
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT MOTIONLESS TIMEOUT SETTING
5
Scan Two Characters From
‘0’, ‘0’ and ‘5’
‘0’, ‘1’ and ‘0’
‘1’, ‘0’, and ‘0’
‘2’, ‘5’, and ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE