Maxicode Length Control
This feature specifies either variable length decoding or fixed length decoding for this
symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
$CMXLC00(CR)
Maxicode Length Control = Variable Length
$CMXLC01(CR)
Maxicode Length Control = Fixed Length
Maxicode
Set Length 1
Specifies one of the barcode lengths for
. Length 1 is the minimum
label length if in
Variable Length
Mode, or the first fixed length if in Fixed Length Mode.
Characters can be set from 0001 to 0145 characters in increments of 0001 (pad with zeroes).
See
for detailed instructions on setting this feature.
$CMXL1
Select Maxicode Length 1 Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE barcode above, then the barcode at
left followed by the digits from the Alphanumeric char-
acters in
representing your
desired character(s). End by scanning the ENTER/EXIT
barcode again.
Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
0001 = Length 1 is 1 Character