TWO CIRCUIT INSTALLATION
1. Connect circuit one black supply wire to line side of one switch. Secure with approved connector
2. Connect supplied black jumper wire from switch, wired to circuit 1, to L-1 terminal on track feed connector
3. Connect circuit one neutral supply wire to N-1 terminal on track feed connector
4. Connect circuit two hot supply wire to line side of remaining switch. Secure with approved connector
5. Connect supplied black jumper wire from switch, wired to circuit 2, to L-2 terminal on track feed connector
6. Connect circuit two neutral supply wire to N-2 terminal on track feed connector
7. Connect ground wire to ground screw
CANOPY INSTALLATION
1. Align cutouts to slide canopy over junction box as shown in diagram. If installing with AKTSL and/or second switch,
remove the appropriate scored tab.
2. Secure canopy to junction box with supplied tamper-resistant
screws, using bit driver provided to tighten screws.
NOTE: IN ORDER TO MEET CALIFORNIA TITLE 24
REQUIREMENTS, CANOPY MUST BE SECURED
WITH VANDEL RESISTANT SCREWS PROVIDED.
OPERATION
After installation is complete, place current limiter switch
in the “on” position to power track. If current draw of
installed heads exceeds maximum ratings on the current
limiter, limiter will automatically switch to “off” position.
If this occurs, reduce the wattage/current draw on the
track to a wattage/current draw lower than the maximum
ratings allowed on the current limiter. Turn current
limiter switch back in the “on” position.
Green Ground Screw
White (Neutral) Wire N2
Black (Hot) Wire L2
Black (Hot) Wire L1
White (Neutral) Wire N1
N1
L2
L1
N2
AKTEF or AKTSL
(ordered separately)
AKTCLS
Current Limiter Switch
6-32x3/8” Pinned Torx
Security Screw