WIRING
NOTE: L-1, L-2 BRASS COLORED TERMINAL
N-1, N-2 NICKEL COLORED TERMINAL
JUMPER WIRES USE 12 GA. STRANDED, UL/CSA LISTED 90 DEGREE WIRE
SHOWN WITH AKTEF. FOR AKTSL, FOLLOW SAME WIRING INSTRUCTIONS
ONE CIRCUIT INSTALLATION – Wired for one side of track
1. Connect black supply wire to line side of switch. Secure with approved connector
2. Connect supplied black jumper wire from switch to L-1 terminal on track feed connector
3. Connect neutral supply wire to N-1 terminal on track feed connector
4. Connect ground wire to ground screw
ONE CIRCUIT INSTALLATION – Wired for both sides of track
1. Connect black supply wire to line side of switch. Secure with approved connector
2. Connect supplied black jumper wire from switch to L-1 terminal on track feed connector
3. Connect neutral supply wire to N-1 terminal on track feed connector
4. Connect black jumper wire (supplied by others) to L-1 terminal and L-2 terminal on track connector
5. Connect white jumper wire (supplied by others) to N-1 terminal and N-2 terminal on track connector
6. Connect ground wire to ground screw
Green Ground Screw
White (Neutral) Wire
Black (Hot) Wire
N1
L1
Green Ground Screw
White (Neutral) Wire
Black (Hot) Wire
AKTEF or AKTSL
(ordered separately)
AKTCLS
Current Limiter Switch
AKTEF or AKTSL
(ordered separately)
AKTCLS
Current Limiter Switch