Instruction sheet – Prescolite ALCF-1, 4, 5, 6 User Manual
Page 2

www
.prescolite.com
• Prescolite
TollFree
Technical Support
1.888.PRS.4TEC
• Hours: 8am - 5pm ET
101 Corporate Drive • Spartanburg, SC 29303
With representatives offices in principal cities throughout North America.
Copyright 2005, 08/05 revision, All Rights Reserved - Printed in U.S.A.
Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .03424500
Instruction
Sheet
Wire Nut
(By Others)
BALLAST
Wiring Diagram
Fig. 4
Faceplate
SOCKET
120V
Supply
(WHT)
(BLK)
(BLK)
Housing
(Installed)
Socket Holder
Plate
5. Make electrical connections. Connect ground wires to green
ground leads. Connect white (common) to white leads. Connect
power supply (line) to black leads. (see wiring diagram).
For through wiring: replace the J-Box cover (Fig. 4). Replace the
socket mounting plate and install lamp. WARNING: DO NOT
pinch wires. Consult a Qualified Electrician for all other
options that require other wiring configurations.
6. Assemble faceplate to the housing (Figure 3)with two (2) 8-32
flathead screws (provided in packet).
7. To relamp fixture:
ALCF-1
Remove faceplate
ALCF-4, 5, & 6
Loosen thumbscrew and
open faceplate door.
Faceplate Installation
Figure 3