Instruction

Sheet

INSTALLATION INSTRUCTIONS

ALCF-1, 4, 5, and 6

1.

Install the housing by nailing the mounting brackets on

the housing to the frame support as shown in Fig. 1, or

frame in the housing as desired for wet or dry wall

construction.

2. Adjust the mounting brackets to locate the housing as

required for profile trim (Fig. 2).

3. Install the conduit (by others) to align with one of three

7/8" diameter knockouts located on the sides and

bottom of housing. Remove the wingnut retaining the

socket mounting plate and lift out plate.

4. When installed in concrete pour or mortar and in a

situation where direct water exposure is frequent, the

concrete or mortar is to be suitably treated with a

sealing or repelling agent to insure that the fixture

housing does not remain continuously wet.

Support Frame

(By Others)

Housing Installation

Figure 1

Conduit

(By Others)

Housing

Fastener (Nail)

(By Others)

Profile Trim

Figure 2

Adjustable Mounting

Bracket (2)

Adjustable

Mounting

Bracket (2)

Conduit

Entry

Profile Trim

(Wet or Drywall

Construction)

Housing

Conduit

(By Others)

IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information

and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,

and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and

during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by

qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.

Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in

compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by

the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from

product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or

the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.