Instruction sheet – Prescolite DLHL User Manual
Page 2
Instruction
Sheet
www
.prescolite.com
Prescolite T
oll Free T
echnical Suppor
t 1.888.PRS.4TEC
Hours: 8am-5pm ET
701 Millennium Blvd., Greenville, SC 29607
With representatives offices in principal cities throughout North America
Copyright ©2013, 7/19/13 All rights reserved • Printed in the USA
Part Number 93014983
2
Instruction
Sheet
www
.prescolite.com
Prescolite T
oll Free T
echnical Suppor
t 1.888.PRS.4TEC
Hours: 8am-5pm ET
2
INSTALLATION IN EXISTING CEILING
CAUTION: BE CAREFULL NOT TO CUT JOISTS, WIRING OR PIPING WHEN CUTTING
THE OPENING IN YOUR CEILING.
1.- DISCARD BAR HANGERS AND CUT A 6-7/8 INCH DIAMETER HOLE IN THE CEILING. PULL ELECTRICAL SUPPLY CABLE DOWN THROUGH
OPENING.
2.- INVERT PLASTER FRAME AND HOUSING ASSEMBLY. REMOVE THREE (3) SHEET METAL SCREWS FROM HOUSING AND SET ASIDE. REMOVE
HOUSING FROM PLASTER FRAME, ALTHOUGH STILL CONNECTED BY CONDUIT. AS PER FIGURE 4, CUT 2 1/2 INCH WIDE NOTCH WITH TIN
SNIPS IN PLASTER FRAME.
3.- MAKE WIRING CONNECTIONS (SEE STEP 2 & 3 ON OTHER SIDE).
4.- TURN PLASTER FRAME ON ITS SIDE AND INSERT ONE LEG INTO HOLE IN CEILING. WHILE SLIGHTLY FLEXING OTHER LEG OF FRAME,
CONTINUE INSERTING FRAME UNTIL JUNCTION BOX CLEARS HOLE IN CEILING (SEE FIGURE 5).
5.- TURN PLASTER FRAME RIGHT-SIDE-UP AND SEAT LIP OF FRAME OPENING INTO HOLE IN CEILING (SEE FIGURE 6).
6.- INSTALL THREE (3) PRESCOLITE RC6 CLIPS (PURCHASED SEPARATELY)ON LIP OF FRAME OPENING, TO KEEP FRAME IN PLACE.
(SEE FIGURE 6)
7.- SLIDE HOUSING BACK INTO PLASTER FRAME. ADJUST TO CEILING HEIGHT AND SECURE IN PLACE WITH THREE (3) SHEET METAL SCREWS.
FIGURE 4
FIGURE 5
FIGURE 6
RC6 CLIPS (3)
(PURCHASED SEPARATELY)
HOUSING
CEILING
JUNCTION BOX
HOLE IN CEILING
INVERTED
PLASTER FRAME
BREAKAWAY
SECTION
HOUSING
PLASTER
FRAME
(3) SHEET METAL *
SCREWS
INSTALLATION IN SUSPENDED CEILING
PLASTER FRAME CAN BE INSTALLED IN SUSPENDED CEILINGS ACCORDING TO INSTRUCTIONS FURNISHED WITH
PROGRESS P8773 SUSPENDED CEILING CLIPS. (PURCHASED SEPARATELY)
FIGURE 4
FIGURE 5
FIGURE 6
RC6 CLIPS (3)
(PURCHASED SEPARATELY)
HOUSING
CEILING
JUNCTION BOX
HOLE IN CEILING
INVERTED
PLASTER FRAME
BREAKAWAY
SECTION
HOUSING
PLASTER
FRAME
(3) SHEET METAL *
SCREWS
2 1/2 INCH NOTCH