beautypg.com

Ins tru ctio n s he et – Prescolite QUARTZ RESTRIKE DCB User Manual

Page 2

background image

3. With the trim ring on the reflector, place the reflector in the housing aperture. Make sure the two mounting screws extend thru the

keyholes in the top of the reflector. Tighten the screws to draw the trim ring up against the ceiling.

4. Install the auxiliary quartz lamp. (See table below for correct lamp.)

Ellipsoidal Reflector Type Housings:

1. The reflectors provided with this type of housing are factory assembled, and it is only necessary to install the cast socketholder

and auxiliary quartz lamp as noted in instructions No. 2 and No. 4 above.

2. Install housing trims.

w
w
w

.p

r

e

s

c

o

li

te

.c

o

m

•P

res

co

lite

To

llF

ree

Te

ch

nic

al

Su

pp

ort

1.8

88

.P

RS

.4T

EC

Ho

urs

:8

am

-5

pm

ET

701 Millennium Blvd., Greenville, SC 29607

With representatives offices in principal cities throughout North America.

Copyright 2007, 05/07 revision, All Rights Reserved - Printed in U.S.A.

Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .03987900

Ins

tru

ctio

nS

he

et

Retaining Clip

Cast Socketholder

Lamp

(By Others)

AUXILIARY LAMP WATTAGE TABLE FOR QUARTZ RESTRIKE

Maximum Wattage for Integral Lamp

Maximum Wattage for Remote Lamp

Wattage of

H.I.D. Lamp

Enclosed Fixtures

Open Fixtures

120V Supply

208/240/277/347V Supply

35W - 100W

100W T4 Quartz

100W T4 Quartz

400W

100W

150W - 175W

100W T4 Quartz

150W T4 Quartz

400W

150W

250W - 400W

150W T4 Quartz

250W T4 Quartz

400W

300W

Reflector

Housings with DCB Option:

1. Follow the instructions outlined above for installing the housing, ballast, voltage selection, and housing reflector types, A-Line or

ellipsoidal.

2. Unlike the housings with Quartz Restrike, the DCB housings are supplied with the leads from the emergency lamp socket unwired.

3. Remove the J-Box Cover(s) and locate the two leads from the emergency lamp socket. Splice these two leads to a separate

emergency circuit. Replace J-Box Cover(s).

CAUTION: Separate DCB circuit is 120V supply only.

4. Install correct quartz lamp per table below.

AUXILIARY LAMP WATTAGE TABLE FOR DCB

Wattage of

Maximum Wattage for Integral Lamp

Standard

Fixture Lamp

Enclosed Fixtures

Open Fixtures

thru 100W

100W T4 Quartz

100W T4 Quartz

150W - 200W

100W T4 Quartz

150W T4 Quartz

250W - 400W

150W T4 Quartz

250W T4 Quartz