Operation – Multiquip WRS5200DFPU (KUBOTA WG972-GL-E3 DUAL FUEL) User Manual
Page 52

page 52 — wrs5200dfpu hYdrauLIC roLLer sCreed • operatIon manuaL — rev. #0 (08/18/14)
operatIon
1. Fully engage the
operator end directional drive tube
control lever in the forward direction.
2. Move the drive tube speed control lever slightly forward
(a few rpm's) and verify that both drive tubes rotate.
3. Fully engage the
operator end directional drive tube
control lever in the reverse (pull back) direction.
4. While drive tube is rotating, push safety bar forward
and verify that drive tube rotation stops.
5. Return operator end directional drive tube control lever
to center position.
6. Move the
power unit end directional drive tube control
lever fully forward and verify that both drive tubes rotate.
7. Next, fully engage the
power unit end drive tube
control lever in the reverse (pull back) direction and
verify that both drive tubes rotate.
8. Return power unit end directional drive tube control
lever to center position.
9. Place the drive tube speed control lever in the
straight
up position (off).
10. Move the strike tube speed and direction control lever
slightly forward. Verify strike tube rotates in a clockwise
rotation. Move lever slightly backwards and verify that
strike tube rotates in a counter-clockwise direction.
11. Screed is now ready for use.
normaL shutdown
1. Press down on the
throttLe switch and listen for
the engine speed to decrese (idle). No
green light.
2. Place the two drive tube directional control levers in
the
middle position (Figure 41).
3. Place the drive tube speed control lever in the
straight
up position.
4. Place the strike tube speed and directional control lever
in the
neutral (center) position.
5. Let engine idle for 2 to 3 minutes.
6. Turn ignition key to the
OFF position.
7. If LP Gas mode was in use,
CLOSE propane tank
shut-off valve (Figure 50). Turn valve knob clockwise
to close valve.
Figure 50. Propane Tank Shut-Off Valve (Closed)
emergenCY shutdown
1. Press down on either one of the two emergency stop
buttons (Figure 40).
oPeration