beautypg.com

Power unit components – Multiquip WRS5200DFPU (KUBOTA WG972-GL-E3 DUAL FUEL) User Manual

Page 29

background image

wrs5200dfpu hYdrauLIC roLLer sCreed • operatIon manuaL — rev. #0 (08/18/14) — page 29

The definitions below describe the controls and functions

of the Power Unit (Figure 11).
1.

propane tank — Holds 33.5 lbs of propane when used

to fuel engine instead of gasoline.

2.

Lifting Bail — Attach a chain, rope or strap to this

lifting bail whenever lifting of the power unit is required.

This bail is installed only on newer units. Make sure

lifting device has adequate lifting capacity for lifting

the power unit.

3.

muffler — Required to reduce noise and emissions.

never touch muffler while it is hot.

4.

emergency stop Button — In the event of an

emergency press this button.

do not use this button

as a method of shutting down the unit. Pull button

outward when restarting.

5.

Air Cleaner — Prevents dirt and other debris

from entering the fuel system. Replace with only

manufacturer recommended type air cleaner.

6.

Engine — The unit uses a 32.5 HP Kubota gasoline/

propane engine. Reference engine owners manual or

maintenance section in this manual for engine care

and service.

7.

hydraulic motor support Bracket — Place strike

tube hydraulic motor into this bracket whenever the

drive tube requires maintenance or disassembly. Insert

cotter-pin to keep motor from falling.

8.

overflow Bottle — Fill with recommended type

coolant. Always maintain proper coolant level.

9.

radiator/Cap — Fill with recommended coolant.

never remove radiator cap while engine is hot. Allow

a sufficient amount of time for radiator to cool before

removing cap.

10.

Steering Handles — Use these handles (2) to steer

and position the power unit.

11.

tires — This unit employs semi-pneumatic tires. The

power unit should

never be towed on a highway.

Always replace tires with original size type tire. Tires

are designed to be puncture proof.

12.

Battery — Provides +12VDC for power unit electronics.

Replace with recommended type battery only.

PoWer Unit comPonents

13.

hydraulic reservoir tank/Cap — Remove this

cap to add hydraulic fluid. Fill with AW MV ISO 46

type hydraulic fluid. Reservoir capacity is 5 gallons

(19 liters).

14.

Hydraulic Fluid Gauge — Displays the amount of

hydraulic fluid in the hydraulic tank. Also the gauge will

display the temperature of the hydraulic fluid.

15.

Quick-disconnect Coupling (output) — Connect

hydraulic motor drive line to this output port. Make

sure to cover coupling with dust cap to prevent dirt

and debris from contaminating hydraulic fluid system.

16.

Quick-disconnect Coupling (return) — Connect

hydraulic motor return line to this input port. Make

sure to cover coupling with dust cap to prevent dirt

and debris from contaminating hydraulic fluid system.

17.

Halogen Lights — Power unit is equipped with four

50-watt halogen lights. Lights can be used when

working in dark areas or at night.

18.

fuel tank — Fill with clean fresh gasoline. Fuel tank

capacity is 5 gallons (19 liters).

19.

Fuel Gauge — Indicates the amount of gasoline in

the fuel tank.

20.

Control Box receptacle — Insert the control box

power cable into this receptacle.

21.

pressure washer (optional) — Removes excess

material.

22.

Control Lever — 3-position lever, pressure washer,

neutral and screed operation.

23.

fuse/relay Box — Replace with only recommended

type fuses or relays.

24.

power relay/ fuse module — Design for high current

applications. Contains 20 and 60 amp fuses. 60 amp

fuse is switchable via relay.

25.

propane tank Gas Gauge — Indicates the amount

of propane in the propane tank.

26.

Igniter — Ignites the engine fuel mixture.