6 close commands for ramp segments, Stops the programme stop, Starts the programme start – Memmert TTC 256 Temperature test chamber (Generation 2003) User Manual
Page 37

37
Operation and control
Each ramp must be completed with a close command connecting the ramp to the next one.
These commands thus control the programme sequence:
loop
t3
t4
t2
t1
on
off
Mo
Tu
We
Th
Fr
Sa
Su
3
4
2
1
STERI
DEFRO
mb
IN 1
IN 2
OUT
MIN
AUTO
MAX
°C
°C
%
rh
h
SETUP
10. Close command of the ramp segment
Setting: NEXT, SPWT (T), SPWT (H), SPWT (TH), LOOP, HOLD, END (shown in picture: Command End;
see also chapter 5.8.6 Close commands for ramp segments on page 37 ).
loop
t3
t4
t2
t1
on
off
Mo
Tu
We
Th
Fr
Sa
Su
3
4
2
1
STERI
DEFRO
mb
IN 1
IN 2
OUT
MIN
AUTO
MAX
°C
°C
%
rh
h
SETUP
11. Leave programming write mode EDIT
Turn push-turn control to the right until EXIT appears in the display, and press the SET key
briefly to confirm.
After releasing the SET key,
►
a new programme can be created
as described above, or an existing
one be edited with EDIT
EDIT
►
stops the programme
STOP
►
starts the programme
START
5.8.6 Close commands for ramp segments
Each ramp must be completed with a close command connecting the ramp to the next one.
These commands thus control the programme sequence:
NEXT
Connect the next programme segment.
SET-POINT WAIT (T – Temperature)
Wait until setpoint has been reached.
Appliance starts the next programme segment only when the
programmed setpoint temperature has been reached, even if the
set heating up time has already elapsed.