6.3.7
FC94 (FC Process Data, 2 words, CP)
Function for process data access
The function
FC94 can be used for both consistent and inconsistent process data transfer.
Parameters
Data type
Possible values/meaning
FirstDriveDW
IN: INT
Byte offset of the first drive data word in the data exchange
DB (decimal)
DriveSend_DB
IN: BLOCK_DB
Data exchange DB for send jobs to the external PROFIBUS
communication processor (CP)
DriveRecv_DB
IN: BLOCK_DB
Data exchange DB for read jobs from the external
PROFIBUS communication processor (CP)
Enable
IN: BOOL
TRUE Drive enabled
Enable
IN: BOOL
FALSE Drive inhibited
QSP
IN: BOOL
TRUE Quick stop (QSP) active
QSP
IN: BOOL
FALSE Quick stop (QSP) not active
Reset
IN: BOOL
FALSE
äTRUE TRIP reset executed
Setpoint1
IN: INT
Setpoint process value (AIF-IN:W1)
ControlWord
IN: WORD
Control word according to DRIVECOM specification
•
Bit0 ... Bit4 are hidden and cannot be written.
RDY
OUT: BOOL
TRUE Drive is ready for operation
OU
OO
FALSE Drive is not ready for operation
TRIP
OUT: BOOL
TRUE Drive signals TRIP
OU
OO
FALSE Drive does not signal TRIP
ActualValue1
OUT: INT
Actual process value (AIF-OUT:W1)
StatusWord
OUT: WORD
Status word according to DRIVECOM specification