Appendix, Table of parameter numbers (pnu) – Lenze 931K User Manual
Page 72

Appendix
Table of parameter numbers (PNU)
l
72
KHB 13.0004−EN 2.1
Characteristics
Possible settings
Name
PNU
Description
Selection
Lenze
Name
PNU
1290
Motor Data
Overload protection for the
motor connected.
0 iit Time Motor
2000
0
{1 ms}
10000
Ċ
UNIT16
RW
Ċ
Time for which the motor is
fed with the specified
maximum current.
l
When the time has
elapsed, the motor
current is automatically
limited to the rated
current set.
1 iit Ratio Motor
{1 }
Ċ
UNIT16
RO
Ċ
Reading−out of the actual
utilisation of the I
2
t
limitation.
1350
0 Enable Logic
0
Ċ
UNIT16
RW
Ċ
Controller is enabled via:
Selection of the source for
controller enable
0
Digital input DIN 9
1
Digital input DIN 9 and RS232
3
Digital input DIN 9 and PROFIBUS
1500
0 Operating Mode
Ċ
UINT8
RO
Ċ
00
h
Speed control
Reading−out of the operating
mode.
10
h
Positioning
1601
Error Code
Error messages
0 Error Field 0
Ċ
UINT32
RO
Ċ
Error numbers 1 ... 32 of the
controller
1 Error Field 1
Ċ
UINT32
RO
Ċ
Error numbers 33 ... 64 of the
controller
1610
Error Management
Error management
0 Error Number
Ċ
UNIT8
RW
Ċ
1
h
{1}
40
h
Selection of the error number
for which a response is to be
set under PNU 1610.1.
Overview of error numbers:
^ 62
1 Error Reaction Code
Ċ
UNIT8
RW
Ċ
00
h
No response
Response of the controller to
an error event.
Notes on settings:
^ 62
03
h
Warning
05
h
Emergency stop
08
h
Power stage off (motor coasts to
standstill)