6 motor data, 7 operating modes, Motor data – Lenze 931K User Manual
Page 42: Operating modes, Commissioning, Actual values motor data, Tlimitation in

Commissioning
Actual values
Motor data
l
42
KHB 13.0004−EN 2.1
6.7.6
Motor data
ƒ
Via PNU 1290.1 (iit Ratio Motor) you can read out the actual utilisation of the I
2
t
limitation in [].
PNU
Name
Possible settings
Characteristics
Lenze
Selection
Description
1160
Temperature
Reading of different
temperatures.
0 Power stage
temperature
{1 °C}
Ċ
INT16
RO
Ċ
Reading of the current power
stage temperature.
1 Motor temperature
{1 °C}
Ċ
INT16
RO
Ċ
Reading of the current motor
temperature.
1290
Motor Data
Overload protection for the
motor connected.
0 iit Time Motor
2000
0
{1 ms}
10000
Ċ
UNIT16
RW
Ċ
Time for which the motor is
fed with the specified
maximum current.
l
When the time has
elapsed, the motor current
is automatically limited to
the rated current set.
1 iit Ratio Motor
{1 }
Ċ
UNIT16
RO
Ċ
Reading−out of the actual
utilisation of the I
2
t
limitation.
6.7.7
Operating modes
PNU
Name
Possible settings
Characteristics
Lenze
Selection
Description
1500
0 Operating Mode
Ċ
UINT8
RO
Ċ
00
h
Speed control
Reading−out of the operating
mode.
10
h
Positioning